GE Healthcare · CTLightSpeedVCT2601331552601331541238326539260101015
LightSpeed 7.x (VCT, VCT Select, Pro32)
Symptom
"Scanner Hardware Stopped Scan" with CAM or Filter errors
Error message
Error: 260133155 CAM (A or B) Motion With Out Command Exceeded The Error Tolerance See Long Description for error detail Sun Jul 11 21:12:37 2010 Error: 260133155 Host: orp Process: orp_subsys File: ccb_drive_timers.cxx Line: 298 Sun Jul 11 21:12:35 2010 Host : Collimator Ermes # : 260133155 Exception Class : Abort Severity : Secondary File : ccb_drive_timers.cxx Line# : 298 Function : No System Function Reported Scan Type : None/Unknown Scan: 0/0/0 . CAM B Motion With Out Command Exceeded The Error Tolerance. Desired Position : 5755um 0cnt Current Position : 5817um -19cnt Error Tolerance: 60um Sun Mar 29 11:16:32 2009 Error: 260133155 Host: orp Process: orp subsys File: ccb drive timers.cxx Line: 298 Sun Mar 29 11:16:31 2009 Host : Collimator Ermes # : 260133155 Exception Class : Abort Severity : Secondary File : ccb drive timers.cxx Line# : 298 Function : No System Function Reported Scan Type : None/Unknown Scan: 0/0/0 CAM A Motion With Out Command Exceeded The Error Tolerance . Desired Position : 6166um 0cnt Current Position : 6394um -77cnt Error Tolerance Error: 260133154 CAM A Motion With Out Command Exceeded The Warning Tolerance Sun Mar 29 11:16:35 2009 Error: 260133154 Hos
Applies to
- Models
- LightSpeed, VCT
- Product
- LightSpeed 7.x (VCT, VCT Select, Pro32) V40_H_V64_G_GTM V40_H_V64_G_GTL V40_H_V32_G_GTM V40_H_V32_G_GTL V40_H_H64_G_GTM V40_H_H64_G_GTL V40_H_HS64_G_G Product Name: LightSpeed 7.x (VCT, VCT Select, Pro32) Product photographs Method of remote or software identification - See attachment for a complete list of software commands and typical results. check_config swhwinfo “swhwinfo” will have the following new switches available with the VCT M4 and PF 1.5 M3 software release (software release deploying this “swhwinfo” capability is “06MW03.?”): · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) · -h or –help = Outputs complete details about all the available switches associated with swhwinfo · swhwinfo –c –m –o -da List of Supported Console Types GOC5 Will have a VDARC and VIG GOC6 Will have a VDIG List of softwares the product can run 09MW08.10 09MW08.11 08MW33.2 07MW18.4 06MW03.4 05MW31.6 FAQ's Table weight limit - Up to 500 lb. (227 kg) with ± .25 mm positional accuracy Tube type - D3194T D3193T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system. Done acording to template
- Component
- 5129998-2 ccb chassis assembly VCT-GAN-COLL This is actually the Collimator Control Board and the metal bracket only - it is NOT the complete collimator assembly. See LD for details 5129998-2 ccb chassis assembly VCT-GAN-COLL This is actually the Collimator Control Board and the metal bracket only - it is NOT the complete collimator assembly Part #: 5129998-2 Part Type: GP CONSUMABLE - RETURNABLE Part Weight: 0.00 LBR Repairable: No Returnable: Yes Hazardous Material: N Description: CCB Chassis Asm, VCT Failsafe VCT-GAN-COLL FRU: Yes Status: Orderable Comments: Added by ECR 2019627, Part of Failsafe Collimator for VCT, ms13452 051015 This part is direct replacement for 5129998, and 5123185. ms13452
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.