GE Healthcare · CTLightSpeedVCT18288322298712256730182872105252372485
LightSpeed 3.X (Ultra, Plus, QX/i) - GRE
Symptom
Cradle unlatches on its own and the scanning aborts
Error message
Error: 182883 An Invalid RESET has been Detected. Node Type: TNC (ETC I/F). See Long Description for more details Mon May 9 13:45:23 2005 Error: 182883 ETC Gantry Display gd tnc erlog.c 611 Function: No System Function Reported Scan: 0/0/0 Type: None/Unknown Exception Level: Pri/Soft Time: 13:45:23:085 Log Series: 39 An Invalid RESET has been Detected. NOTE: Reset Reason of 0x60 is Expected after FLASH Download. Reset Reason: 0x10. Node Id: 0 Node Type: TNC (ETC I/F). Board Number: 2229871 Serial Number: 0. OR Error: 182883 Host: ETC Process: Gantry Display File: gd_tnc_erlog.c Line: 611 Function: No System Function Reported Scan: 0/0/0 Type: None/Unknown Exception Level: Pri/Soft Time: 21:24:30:390 Log Series: 10 An Invalid RESET has been Detected. NOTE: Reset Reason of 0x60 is Expected after FLASH Download. Reset Reason: 0xe2. Node Id: 1 Node Type: GANTRY DISPLAY. Board Number: 2256730 Serial Number: 7596. Error: 182872 TNC Controller Received an Invalid Command. See LD for more details Error: 182872 TNC Controller Received an Invalid Command. Thu May 25 08:19:06 2006 Error: 182872 Host: ETC Process: Gantry Display File: gd_tnc_erlog.c Line: 505 Function: No System Function Repo
Applies to
- Models
- LightSpeed, VCT
- Product
- LightSpeed 3.X (Ultra, Plus, QX/i) - GRE Always 4 or 8 slice MDAS. H2_P_M4 H2_P_M8 LightSpeed 3.X - GRE Method of visual identification Small rounded gantry similar in appearance to LS 2.X and 4.X. Always has an MDAS4 or MDAS8 Method of remote or software identification - See attachment below for a complete list of software commands and typical results. check_config “swhwinfo” will have the following new switches available with the VCT M4 and PF 1.5 M3 software release (software release deploying this “swhwinfo” capability is “06MW03.?”): · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) -h or –help = Outputs complete details about all the available switches associated with swhwinfo swhwinfo –c –m –o -da Always has an MDAS4 or MDAS8 List of Supported Console Types GOC3 Will have a DARC, SDDA and IG GOC4 Will have a DARC 2 and IG List of softwares the product can run 07MW11.10 SP3 06MW29.7 - obsolete 06MW03.5 - obsolete 05MW14.5 - obsolete 04MW44.9 - obsolete 04MW13.7 - obsolete FAQ's Table weight limit - Up to 400 lb. (180 kg) with ± .25 mm positional accuracy. 450Ib (205 kg) max weight Tube type - D3186T Current production details - See Technical Reference Manual found on the Common Document Library Tips and workarounds, where to find it - Common Document Library(CDL) . Search for the latest FMI software release. In the furnished materials will be the list of various manuals with part numbers for the various languages. Example: English versions 2211223-100 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Component
- 2372485 ETC IF (Interface or TNC Bd.) Replaces 2229871 See long description for details 2372485 ETC IF (Interface or TNC Bd.) Replaces 2229871 Part #: 2372485 Part Type: GP CONSUMABLE - RETURNABLE Part Weight: 0.00 LBR Repairable: No Returnable: Yes Hazardous Material: N Description: ETC INTERFACE W/ AZ60A FRU: Yes Status: Orderable Comments: FLS - ETC INTERFACE W/ AZ60A. ADDED PER PCN 220857. REPLACES P/N 2229871. USE UP EXISTING STK. MS20544 5/1/03. ONE USE LIGHTSPEED PLUS VC:611695-SCI, RAPID CITY, SD CONTROL PCB 46-264368G3
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required