GE Healthcare · CT1837051090731
Lightspeed 1.X - Octane
Symptom
Intermittent Console Keyboard Lockups See long description for details Intermittent Console Keyboard Lockups Tue May 8 13:15:55 2007 Error: 183705 Suite: CT01 Host: STC Process: Console Pushbuttons File: cp_wdog.c 1.23 Method: No Method Line: 289 Function: No System Function Reported Scan: 0/0/0 Type: None/Unknown Exception Level: Pri/Most Severe Time: 1090731 Log Series: 0 Console Push Button Watchdog Timeout. HW Error: Possible hardware problem.
Applies to
- Product
- Lightspeed 1.X - Octane 10.5_2.8.2I_H1.3M4 10.4.1_2.8.2I_H1.3M4 - obsolete Lightspeed 1.X - Octane Method of visual identification Method of remote or software identification - See attachment below for a complete list of software commands and typical results. check_config showprods|grep Apps note: if check_config does not work then the software is not up to date with all FMI's. Check FMI history and verify that all patches have been loaded since last software reload. Ref FMI 25269 List of Supported Console Types Octane with Pegasus Recon hardware. may have an 02 SBC - Run df -k to see if the sbc is partitioned. List of softwares the product can run 10.5_2.8.2I_H1.3M4 10.4.1_2.8.2I_H1.3M4 - obsolete FAQ's Table weight limit - Up to 400 lb. (180 kg) with ± .25 mm positional accuracy. 450Ib (205 kg) max weight Tube type - D3176T Current production details - See Technical Reference Manual found on the Common Document Library Tips and workarounds, where to find it - Common Document Library(CDL) . Search for the latest FMI software release. In the furnished materials will be the list of various manuals with part numbers for the various languages. Example: English versions 2211223-100 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Component
- 2275756 keyboard - NORTH AMERICAN PC PS/2 See the long description for details Part #: 2275756 Part Type: GP CONSUMABLES Part Weight: 1.36 LBR Repairable: No Returnable: No Hazardous Material: N Description: KEYBOARD, NORTH AMERICAN PC PS/2 FRU: Yes Status: Orderable Comments: FLS - H2 ENGLISH SCIM KEYBOARD. DSM 2262158-9, 2275756, AND 2289697-2 ARE REPLACING 2276441-10. ALL THREE PARTS ARE REQUIRED TO REPLACE 2276441-10. USE EXISTING STOCK FIRST OF 2276441-10 PER PCN 224305. 01/04/02 FOUR PARTS (2262158-9, 2275756, 2289697-2, AND 2289697-8) ARE REQUIRED TO REPLACE ANY OF THE FOLLOWING: 2276441-4, 2276441-5, 2276441-6, 2276441-7, 2276441-11, OR 2276441-12. PER PCN 224305, 224332, AND 224426. 04/05/02
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required