LightSpeed 7.x (VCT, VCT Select, Pro32)

Symptom

Heart rate is not stable on OC Console display but consistent on ECG Monitor See Long Description EKG trace during scan not accurate. Patients heartrate checked at 50 beats a minute, but trace indicates 178 beats.

Error message

Error: 260100107 The current gating status indicates a LATE R-peak See long description Thu Oct 22 10:25:51 2009 Error: 260100107 Host: tgp Process: tgp_subsys File: scExternalGate.c Line: 1314Thu Oct 22 10:25:51 2009Host : Table Gantry Processor Ermes # : 260100107Exception Class : Secondary Severity : Pri/SoftFile : scExternalGate.c Line# : 1314Function : No System Function ReportedScan Type : None/Unknown Scan: 0/0/0WARNING: The current gating status indicates a LATE R-peak. Current gating signal time = 10441520 msLast gating signal time = 10440260 msDifference between current and last gating signal = 1260 msCurrent median = 865 ms

Applies to

Models
LightSpeed, VCT
Product
LightSpeed 7.x (VCT, VCT Select, Pro32) V40_H_V64_G_GTM V40_H_V64_G_GTL V40_H_V32_G_GTM V40_H_V32_G_GTL V40_H_H64_G_GTM V40_H_H64_G_GTL V40_H_HS64_G_G Product Name: LightSpeed 7.x (VCT, VCT Select, Pro32) Product photographs Method of remote or software identification - See attachment for a complete list of software commands and typical results. check_config swhwinfo “swhwinfo” will have the following new switches available with the VCT M4 and PF 1.5 M3 software release (software release deploying this “swhwinfo” capability is “06MW03.?”): · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) · -h or –help = Outputs complete details about all the available switches associated with swhwinfo · swhwinfo –c –m –o -da List of Supported Console Types GOC5 Will have a VDARC and VIG GOC6 Will have a VDIG List of softwares the product can run 09MW08.10 09MW08.11 08MW33.2 07MW18.4 06MW03.4 05MW31.6 FAQ's Table weight limit - Up to 500 lb. (227 kg) with ± .25 mm positional accuracy Tube type - D3194T D3193T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system. Done acording to template
Component
5112819-3 ECG, LOW-NOISE, LEAD WIRES, 24in LONG, SET OF 3 see LD 5112819-3 ECG, LOW-NOISE, LEAD WIRES , 24in LONG, SET OF 3 Part #: 5112819-3 Part Type: GP CONSUMABLES Part Weight: 0.00 LBR Repairable: No Returnable: No Hazardous Material: N Description: ECG, LOW-NOISE, LEAD WIRES, 24in LONG, SET OF 3 FRU: Yes Status: Orderable 5112819-2 ECG, 3-LEAD, LOW-NOISE PATIENT CABLE, 3m LONG see LD 5112819-2 ECG, 3-LEAD, LOW-NOISE PATIENT CABLE , 3m LONG Part #: 5112819-2 Part Type: GP CONSUMABLES Part Weight: 0.00 LBR Repairable: No Returnable: No Hazardous Material: N Description: ECG, 3-LEAD, LOW-NOISE, PATIENT CABLE, 3m LONG FRU: Yes Status: Orderable 5198566 cable-gantry - EKG PRO See Long Discription for Details Part #: 5198566 Part Type: GP CONSUMABLES Part Weight: 0.00 LBR Repairable: No Returnable: No Hazardous Material: N Description: cable-gantry - exg pro FRU: Yes Status: Orderable
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.