GE Healthcare · CTLightSpeed210000428210000430210000431210000447200002357
LightSpeed RT16 & RT16 Xtra
Symptom
System fails to reconstruct images. System fails to reconstruct images
Error message
Error: 210000428 Unable to establish connection for repository iosterra|terradb session See long description for full error Tue Jan 29 06:51:29 2008 Error: 210000428 Host: gevct2 Process: dms File: Initialize.cxx Line: 396 Unable to establish connection for repository iosterra|terradb session Error: 210000430 Failed to initialize SaveContext with status -1 See long description for sample error. Tue Mar 18 08:58:45 2008 Error: 210000430 Host: jghls64 Process: dms File: Initialize.cxx Line: 410 Failed to initialize SaveContext with status -1 Error: 210000431 Failed to intialize client session for save context with error 2 See long description for sample error. Tue Mar 18 08:58:45 2008 Error: 210000431 Host: jghls64 Process: dms File: SaveContext.cxx Line: 41 Failed to intialize clien session for save context with error 2 Error: 210000447 unable to connect to session dms_session with error code -2 See long description for details Tue Jan 29 06:51:29 2008 Error: 210000447 Host: gevct2 Process: dms File: DMFInstall.cxx Line: 229 Error: unable to connect to session dms_session with error code -2 error message Session Not Connected Error: 200002357 A HOST SHUTDOWN was initiatied by th
Applies to
- Models
- LightSpeed
- Product
- LightSpeed RT16 & RT16 Xtra and Vision WB_H_G16_G_GTL = RT16, Xtra WB_H_G16_G_GTL650 = Vision WB_H_G16_G_GTM = RT16, Xtra or Vision LightSpeed RT16 & RT16 Xtra with GRE and GDAS16 gantry Links to the Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Software
- 08BW44.1 Software for all BrightSpeed Systems with AIO Console and all RT16 Systems with GOC4 Console See Long Description 08BW44.1 Software is used on all BrightSpeed Systems with AIO Consoles and all RT16 Systems with GOC4 Consoles. Software collector called “08BW44.X” p/n 5328867 contains the following items: 5323837 - LightSpeed Xtream Console Operating System Version - GEMS Linux 6.3.8 5323838 - LightSpeed Applications Software DVD Version 08BW44.X 5328828 - Xtream Serial-Over-LAN Service Software Version - 2.0 Supports: Westville or Jarrell DARC/VDARC 5323839 - Class C 5323840 - Class M NOTE: Class C/M install CD are not shipped with system. NOTE: The Xtream Serial-Over-Lan Service Software is not used during the LFC unless instructed via a pop-up message box "SOL Service - ...run the Serial Over LAN Service CD...". This CD is loaded directly into the DARC Node. Then press the reset (or cycle power) at the front panel of the DARC Node as required. This CD will auto-eject when the SOL load process is complete. NOTE: The Xtream Serial-Over-Lan CD is not used for All-In-One Console.
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required