GE Healthcare · CTLightSpeedVCT2601331935017926013316326013316926013319450011
LightSpeed 7.x (VCT, VCT Select, Pro32)
Symptom
Scanner Hardware Stopped Scan. Scanner Hardware Stopped Scan
Error message
Error: 260133193 - Filter A failed to Home (or Filter B failed to Home) See long description for complete error code Sun Mar 18 05:49:17 2007 Error: 260133193 Host: orp Process: orp_subsys File: filter_home.cxx Line: 158 Sun Mar 18 05:49:16 2007 Host : Collimator Ermes # : 260133193 Exception Class : Abort Severity : Primary File : filter_home.cxx Line# : 158 Function : No System Function Reported Scan Type : None/Unknown Scan: 50179/7/0 Filter A failed to Home. OR it could be filter A and B. Sun Mar 18 05:49:17 2007 Error: 260133193 Host: orp Process: orp_subsys File: filter_home.cxx Line: 165 Sun Mar 18 05:49:16 2007 Host : Collimator Ermes # : 260133193 Exception Class : Abort Severity : Secondary File : filter_home.cxx Line# : 165 Function : No System Function Reported Scan Type : None/Unknown Scan: 50179/7/0 Filter B failed to Home. Error: 260133163 CAM (A or B) Move Is Out of The Retry Tolerance. See LD for complete error Sun Sep 10 15:17:52 2006 Error: 260133163 Host : Collimator Ermes # : 260133163 Exception Class : Secondary Severity : Pri/Soft File : ccb_drive_move.cxx Line# : 341 Function : No System Function Reported Scan Type : None/Unknown Scan: 5220/1/0 CAM A Move I
Applies to
- Models
- LightSpeed, VCT
- Product
- LightSpeed 7.x (VCT, VCT Select, Pro32) V40_H_V64_G_GTM V40_H_V64_G_GTL V40_H_V32_G_GTM V40_H_V32_G_GTL V40_H_H64_G_GTM V40_H_H64_G_GTL V40_H_HS64_G_G Product Name: LightSpeed 7.x (VCT, VCT Select, Pro32) Product photographs Method of remote or software identification - See attachment for a complete list of software commands and typical results. check_config swhwinfo “swhwinfo” will have the following new switches available with the VCT M4 and PF 1.5 M3 software release (software release deploying this “swhwinfo” capability is “06MW03.?”): · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) · -h or –help = Outputs complete details about all the available switches associated with swhwinfo · swhwinfo –c –m –o -da List of Supported Console Types GOC5 Will have a VDARC and VIG GOC6 Will have a VDIG List of softwares the product can run 09MW08.10 09MW08.11 08MW33.2 07MW18.4 06MW03.4 05MW31.6 FAQ's Table weight limit - Up to 500 lb. (227 kg) with ± .25 mm positional accuracy Tube type - D3194T D3193T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system. Done acording to template
- Component
- 5129998-2 ccb chassis assembly VCT-GAN-COLL This is actually the Collimator Control Board and the metal bracket only - it is NOT the complete collimator assembly. See LD for details 5129998-2 ccb chassis assembly VCT-GAN-COLL This is actually the Collimator Control Board and the metal bracket only - it is NOT the complete collimator assembly Part #: 5129998-2 Part Type: GP CONSUMABLE - RETURNABLE Part Weight: 0.00 LBR Repairable: No Returnable: Yes Hazardous Material: N Description: CCB Chassis Asm, VCT Failsafe VCT-GAN-COLL FRU: Yes Status: Orderable Comments: Added by ECR 2019627, Part of Failsafe Collimator for VCT, ms13452 051015 This part is direct replacement for 5129998, and 5123185. ms13452
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required