GE Healthcare · CTHiSpeedLightSpeed183163183118216761831212257550013
HiSpeed CTi 6.X with Octane and HSA Gantry
Symptom
Could not scan on small filament
Error message
Error: 183163 MA fault detected. Filament inverter disabled. see long description for complete error Thu Dec 17 14:54:03 2009 Error: 183163 Host: OBC Process: Generator File: gen_control.c 1.39 Line: 595 Function: No System Function Reported Scan: 7091/2/1 Type: Helical Exception Level: Pri/Soft Time: 14:54:03:535 Log Series: 855 MA fault detected. Filament inverter disabled. Error: 183118 - FIL/MA fault detected: Filament current less than 1 Amp. See long description for full error Thu Oct 28 12:14:31 2004 Error: 183118 Host: OBC Process: Generator File: gen_abort.c 1.31 Line: 337 Function: XRAY GENERATION : Filament Selection Scan: 21676/1/1 Type: Scout Exception Level: Pri/Most Severe Time: 12:14:32:370 Log Series: 7 FIL/MA fault detected: Filament current less than 1 Amp. Desired focal spot = 1. (0 = large, 1 = small) Fault latch address = ffdf43 hex, Bit = D4 Error: 183121 FIL/MA fault detected: Open filament circuit. See the long descripton for the full error code Tue Oct 11 13:12:27 2005 Error: 183121 Host: OBC Process: Generator Function: XRAY GENERATION : Filament Selection Scan: 22575/2/1 Type: Helical Exception Level: Pri/Most Severe FIL/MA fault detected: Open filamen
Applies to
- Models
- HiSpeed, LightSpeed
- Product
- HiSpeed CTi 6.X HiSpeed CTi 6.X with Octane and HSA Gantry HiSpeed CTi 6.X with Octane and HSA Gantry Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Component
- 2154834 MA Board used on (CT/i,1.X-4.X) scanners See Long Description for more Part #: 2154834 Part Type: GP CONSUMABLE - RETURNABLE Part Weight: 1.81 LBR Repairable: No Returnable: Yes Hazardous Material: N Description: MA CONTROL BRD./CANCEL FRU: Yes Status: Orderable Comments: FLS - MA BOARD USED ON FAST RHAPSODE FMI#25238 UPGRADES THIS BD. TO A REV.1 ONE USE LIGHTSPEED ULTRA HQT WARNING!! MATERIAL MUST BE PURCHASED FROM MFGING DO NOT GO TO VENDOR AS IT MUST BE TESTED IN MFGING BEFORE SHIPPED TO FIELD VERY VERY HIGH DOA RATE. MS08992 GVR 7/31/00GELS
- Area
- CT