Pular para o conteúdo principal
GE Healthcare · CTHiSpeedLightSpeed183163183118216761831212257550013

HiSpeed CTi 6.X with Octane and HSA Gantry

Symptom

Could not scan on small filament

Error message

Error: 183163 MA fault detected. Filament inverter disabled. see long description for complete error Thu Dec 17 14:54:03 2009 Error: 183163 Host: OBC Process: Generator File: gen_control.c 1.39 Line: 595 Function: No System Function Reported Scan: 7091/2/1 Type: Helical Exception Level: Pri/Soft Time: 14:54:03:535 Log Series: 855 MA fault detected. Filament inverter disabled.

Error: 183118 - FIL/MA fault detected: Filament current less than 1 Amp. See long description for full error Thu Oct 28 12:14:31 2004 Error: 183118 Host: OBC Process: Generator File: gen_abort.c 1.31 Line: 337 Function: XRAY GENERATION : Filament Selection Scan: 21676/1/1 Type: Scout Exception Level: Pri/Most Severe Time: 12:14:32:370 Log Series: 7 FIL/MA fault detected: Filament current less than 1 Amp. Desired focal spot = 1. (0 = large, 1 = small) Fault latch address = ffdf43 hex, Bit = D4

Error: 183121 FIL/MA fault detected: Open filament circuit. See the long descripton for the full error code Tue Oct 11 13:12:27 2005 Error: 183121 Host: OBC Process: Generator Function: XRAY GENERATION : Filament Selection Scan: 22575/2/1 Type: Helical Exception Level: Pri/Most Severe FIL/MA fault detected: Open filamen

Applies to

Models
HiSpeed, LightSpeed
Product
HiSpeed CTi 6.X HiSpeed CTi 6.X with Octane and HSA Gantry HiSpeed CTi 6.X with Octane and HSA Gantry Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
Component
2154834 MA Board used on (CT/i,1.X-4.X) scanners See Long Description for more Part #: 2154834 Part Type: GP CONSUMABLE - RETURNABLE Part Weight: 1.81 LBR Repairable: No Returnable: Yes Hazardous Material: N Description: MA CONTROL BRD./CANCEL FRU: Yes Status: Orderable Comments: FLS - MA BOARD USED ON FAST RHAPSODE FMI#25238 UPGRADES THIS BD. TO A REV.1 ONE USE LIGHTSPEED ULTRA HQT WARNING!! MATERIAL MUST BE PURCHASED FROM MFGING DO NOT GO TO VENDOR AS IT MUST BE TESTED IN MFGING BEFORE SHIPPED TO FIELD VERY VERY HIGH DOA RATE. MS08992 GVR 7/31/00GELS
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.

7-day free trial · no credit card required

Related GE Healthcare CT issues