GE Healthcare · CTLightSpeedVCT23001782829001201023000700223000701450029
LightSpeed 7.x (VCT, VCT Select, Pro32)
Symptom
Cannot peform BOW scans after tube change
Error message
Error: 230017828 X-ray beam edge not detected on channel X row X (zero based). Check Z-alignment. If Z-alignment is within spec, check DAS/Detector for given channel and row. See long description Sat Apr 19 02:58:40 2008 Error: 230017828 Host: ctls Process: accs File: collSweepProcessing.c Line: 2365 ACCS ColimatorCal: Processing: large spot 32x1.25 X-ray beam edge not detected on channel 0 row 0 (zero based). Check Z-alignment. If Z-alignment is within spec, check DAS/Detector for given channel and row. Notes on this error. Channel number is 1 less than Detector Channel number. (ie Zero based numbering) So if the channel number is listed as 0 (zero) Detector Channel is 1 and it is on FRDM 1. If the channel number is 448 then that is the same as Detector channel number is 449 and it is on FRDM 29 Error: 290012010 Wrong corr type for det XX row XX correction type 0 (BAD_DET_NO_CORR) Sun Apr 12 13:37:20 2009 Error: 290012010 ig1 image_generation BadDet.cpp 292 Wrong corr type for det 35 row 1 correction type 0 (BAD_DET_NO_CORR) exam/series/scan = -1/-1/0 Sun Apr 12 13:37:20 2009 Error: 290012010 ig1 image_generation BadDet.cpp 292 Wrong corr type for det 36 row 1 correction type 0 (
Applies to
- Models
- LightSpeed, VCT
- Product
- LightSpeed 7.x (VCT, VCT Select, Pro32) V40_H_V64_G_GTM V40_H_V64_G_GTL V40_H_V32_G_GTM V40_H_V32_G_GTL V40_H_H64_G_GTM V40_H_H64_G_GTL V40_H_HS64_G_G Product Name: LightSpeed 7.x (VCT, VCT Select, Pro32) Product photographs Method of remote or software identification - See attachment for a complete list of software commands and typical results. check_config swhwinfo “swhwinfo” will have the following new switches available with the VCT M4 and PF 1.5 M3 software release (software release deploying this “swhwinfo” capability is “06MW03.?”): · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) · -h or –help = Outputs complete details about all the available switches associated with swhwinfo · swhwinfo –c –m –o -da List of Supported Console Types GOC5 Will have a VDARC and VIG GOC6 Will have a VDIG List of softwares the product can run 09MW08.10 09MW08.11 08MW33.2 07MW18.4 06MW03.4 05MW31.6 FAQ's Table weight limit - Up to 500 lb. (227 kg) with ± .25 mm positional accuracy Tube type - D3194T D3193T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system. Done acording to template
- Component
- 5136400 FRDM Outer Digital Module Kit - VDAS-64 (IF NO STOCK order 5202049) Part #: 5136400 Part Type: GP CONSUMABLE - RETURNABLE Part Weight: 0.00 LBR Repairable: No Returnable: Yes Hazardous Material: N Description: FRDM Detector Module Kit VCT64 FRU: Yes Status: Orderable Parts Offered as: Current: 5136400 Harvested: Not Available Exchange: Not Available Comments: ** FE ASSIST ** This is single outer VDAS64 Detector Module for field replacement (slots 1-26, 32-57 only). Order 5136400-3 for center slots. IF NO STOCK order 5202049 (July 22,2011) *** 2ND OPINION NOTES *** Run the maRatio test and verify the detector module is causing the issue. *** please refer to SN06101714b which recommends tightening the three torque screws for the flex connector to correct for open channels and send an email to [email protected] with results. (212001261 12/21/07) The FRDM handle is no longer in the kit. The handle is part of the DAS/Detector service kit sent with each system. If an FRDM handle is not available hold onto the digital cable screws to remove FRDM module This kit includes the following items: Part Number Description 5125342 FRDM Detector Module Assembly 5125344 Controlled Seating Tool 5134603 Bias Tool 5135869 FRDM Multi-tool 5122218 Spare Wedge Clamp 5116011 Spare Light Seal Clips 5136858 Torx Power Bit T20 2207303-6 Box of Nitrile Gloves, Large 2207303-7 Box of Nitrile Gloves, Extra Large 2269959 Large Blue Dissipate Lab Coat 5134848 Flange Socket M3x6 5151373 Hex Bit 2.5mm 5151374 Hex Bit 3.0mm Plus additional screw and washer hardware spares
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required