Cradle will move a few inches and stop.
Symptom
Cradle will move a few inches and stop. Cradle will move in a few inches and stop
Error message
Error: 260134632 Cradle velocity is out of tolerance see long description for full error Error:260134632 Host: tgp Process: tgp subsys File: gtcb velocity chk.cxx Line: 324 Host : Table Sub-System Ermes # : 260134632 Exception Class : Secondary Severity : Pri/Soft File : gtcb velocity chk.cxx Line# : 324 Function : No System Function Reported Cradle velocity is out of tolerance. current pos (um) : 1387870 velocity tole(um/s) : 75000 expected vel (um/s) : 150000 current vel (um/s) : 71812 start pos (um) : 747630 samples:111 at spd loc:101 cntr:125 pos[at spd loc]:1328930
Applies to
- Models
- Discovery, LightSpeed
- Product
- Discovery CT750 HD V40_PS_HD64_G_GTL V40_PS_HD64_G_GTM Discovery HD CT750 Method of visual identification HD gantry: Gray top and Gray Side covers with HD Markings Console Type: GOC6 has black SCIM and tower face Method of remote or software identification - See attachment below for a complete list of software commands and typical results. check_config swhwinfo “swhwinfo” will have the following new switches available · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) -h or –help = Outputs complete details about all the available switches associated with swhwinfo swhwinfo –c –m –o -da List of softwares the product can run (Consult attached FCT Software Cross Reference): 08MW39.4 - M3 (see attachement for M3 available options) 09MW29.14 - M4 (HD Options = M3 plus Gemstone Spectral Imaging, Gemstone Spectral Review and volume Helical Shuttle ) Example: Of difference with options software [insite@ct01 ~]$ swokinstall -p Product Software Option Keys: Gemstone Spectral Imaging Permanent HelicalShuttle Permanent Xtream Recon Permanent FAQ's Table weight limit: 500 lbs Tube Type - D3702T Green D3701T Current production - M4 Refer to product data sheets or Technical reference Manual, English 5317222-1EN Revision : 2 or later Refer to Application Tips and Work-Arounds Direction 5311815-1EN Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required