Symptom

Table will not move. Table will not move

Error message

Error: 260134712 Elevation characterization data is invalid See long description Wed Jun 30 12:23:15 2010 Error: 260134712 Host: tgp Process: tgp_subsys File: gtcb_emc_char.cxx Line: 165 Running Version Management Tool Wed Jun 30 12:23:14 2010 Host : Table Sub-System Ermes # : 260134712 Exception Class : Secondary Severity : Pri/Soft File : gtcb_emc_char.cxx Line# : 165 Function : No System Function Reported Scan Type : None/Unknown Scan: 0/0/0 . Elevation characterization data is invalid. Execute elevation characterization again.

Error: 260134619 Cradle linear scale error not cleared. Please check cable connection See Long Description for error example Fri Mar 24 13:32:41 2006 Error: 260134619 Host: tgp Process: tgp_subsys File: gtcb_cmc_drv_req.cxx Line: 885 Fri Mar 24 13:32:41 2006 Host : Table Sub-System Ermes # : 260134619 Exception Class : Secondary Severity : Pri/Soft File : gtcb_cmc_drv_req.cxx Line# : 885 Function : No System Function Reported Scan Type : None/Unknown Scan: 0/0/0 Cradle linear scale error not cleared. Please check cable connection <This could be your problem

Error: 260134635 Value attempted to set cradle register is over the max See long description Wed 

Applies to

Models
LightSpeed, VCT
Product
LightSpeed 7.x (VCT, VCT Select, Pro32) V40_H_V64_G_GTM V40_H_V64_G_GTL V40_H_V32_G_GTM V40_H_V32_G_GTL V40_H_H64_G_GTM V40_H_H64_G_GTL V40_H_HS64_G_G Product Name: LightSpeed 7.x (VCT, VCT Select, Pro32) Product photographs Method of remote or software identification - See attachment for a complete list of software commands and typical results. check_config swhwinfo “swhwinfo” will have the following new switches available with the VCT M4 and PF 1.5 M3 software release (software release deploying this “swhwinfo” capability is “06MW03.?”): · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) · -h or –help = Outputs complete details about all the available switches associated with swhwinfo · swhwinfo –c –m –o -da List of Supported Console Types GOC5 Will have a VDARC and VIG GOC6 Will have a VDIG List of softwares the product can run 09MW08.10 09MW08.11 08MW33.2 07MW18.4 06MW03.4 05MW31.6 FAQ's Table weight limit - Up to 500 lb. (227 kg) with ± .25 mm positional accuracy Tube type - D3194T D3193T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system. Done acording to template
Component
5245271 GTCB3 (Global Table Control Board 3) This board replaces 5142177-3 GTCB2 and GTCB part # 5112470 thru 5112470-5, and 5142177. See long description for details Part #: 5245271 Part Type: GP CONSUMABLES Part Weight: 0.00 LBR Repairable: No Returnable: No Hazardous Material: N Description: GTCB3 BOARD ASSY FRU: Yes Status: Orderable Comments: added per to ECO2080741 by sso#305010201 in May 8, 2009. Part will be available end of Sep, 2009, please order old p/n before new p/n on shelf. 5122207-2 ABSOLUTE ENCODER FOR CRADLE GT (replaces 5122207) See long description for details Part #: 5122207-2 ABSOLUTE ENCODER FOR CRADLE GT (replaces 5122207) Part Type: GP CONSUMABLES Part Weight: 2.18 LBR Repairable: No Returnable: No Hazardous Material: N Description: ABSOLUTE ENCODER FOR CRADLE GT FRU: Yes Status: Orderable Comments: This part is used in GT-1700mm and GT-2000mm tables. Not Available
Area
CT