Symptom

Scanner Hardware Stopped Scan. Scanner Hardware Stopped Scan

Error message

Error: 260118236 - (70-0501) DC bus out of range Wed Nov 26 12:56:16 2003 Error: 260118236 Host: orp Process: orp_subsys File: gen_exec.c Line: 1923 Wed Nov 26 12:56:14 2003 Host : Jedi Ermes # : 260118236 Exception Class : Abort Severity : Primary File : gen_exec.c Line# : 1923 Function : No System Function Reported Scan Type : Static Scan: 54034/1/4 (70-0501)DC bus out of range. Z6,Z7= 0h,0h

Error: 260118220 (60-0325) DSP overload See Long Description Sun May 30 15:50:49 2010 Error: 260118220 Host: orp Process: orp_subsys Host : Jedi Ermes # : 260118220 Exception Class : Abort Severity : Primary Scan Type : Helical Scan: 9451/2/2 . (60-0325)DSP overload Code 60 Exposure Errors Error code: 60-0325H Message/explanation: DSP overload Default in kV regulation calculation Potential cause: Main supply Inverter current measurement PPC kV control board Inverter HV tank defective Check main DCBUS voltage on inverter Recommended action/ Troubleshooting guide: Check if transformer currents measurement is correctly plugged inside the inverter (J1 in GateCmd board or J19 in CT IF board). Take some exposures. If error persists, investigate those 2 root causes: 1. Inverter / kV Ctrl: run Inver

Applies to

Models
LightSpeed, VCT
Product
LightSpeed 7.x (VCT, VCT Select, Pro32) V40_H_V64_G_GTM V40_H_V64_G_GTL V40_H_V32_G_GTM V40_H_V32_G_GTL V40_H_H64_G_GTM V40_H_H64_G_GTL V40_H_HS64_G_G Product Name: LightSpeed 7.x (VCT, VCT Select, Pro32) Product photographs Method of remote or software identification - See attachment for a complete list of software commands and typical results. check_config swhwinfo “swhwinfo” will have the following new switches available with the VCT M4 and PF 1.5 M3 software release (software release deploying this “swhwinfo” capability is “06MW03.?”): · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) · -h or –help = Outputs complete details about all the available switches associated with swhwinfo · swhwinfo –c –m –o -da List of Supported Console Types GOC5 Will have a VDARC and VIG GOC6 Will have a VDIG List of softwares the product can run 09MW08.10 09MW08.11 08MW33.2 07MW18.4 06MW03.4 05MW31.6 FAQ's Table weight limit - Up to 500 lb. (227 kg) with ± .25 mm positional accuracy Tube type - D3194T D3193T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system. Done acording to template
Component
2368331-3 INVERTER-AUXILIARY PARTS FOR CT See Long Description for Individual Parts in this kit Part #: 2368331-3 Part Type: GP CONSUMABLES Part Weight: 0.00 LBR Repairable: No Returnable: No Hazardous Material: N Description: INVERTER-AUXILIARY PARTS FOR CT FRU: Yes Status: Orderable Comments: Contents are as follows: Note: Individual parts may not be orderable by design. These are only available as a kit. 5113800 DC BUS Flat Cable 5114266 DC Bus Flat Cable Conductor A 5114267 DC Bus Flat Cable Conductor B 99002539 GAINE THERMO BLC D38/19 MARQ UL 2294112 BUSHING,NEOP, D30/40 HOLE D35 THK1.5 2328760 JH4 INVERTER TANK KV MEASURE CABLE 2227702-3 CONNECTOR 2.54MM TRANSITION, 20POS RECEPTACLE, 0.8UM GOLD, IDC FOR RIBBON CABLE, STRAIN RELIEF, CENTERBUMP 99142110 CABL PL RD 1,27 20C AWG28 300V BL 91612905 MARKING LABEL WHT/TRANSP 25X19 BAND 2108663-3 CLAMP,CLOSED/CABL D6.4X9.5 METAL M4 2375952 RUBAN ADHES CU GAUF 12.7MM L16.5M 2192410-2 SCREW HEXAGON SOCKET 4 MM 8 MM 2229255-3 WASHER LOCK - SPRING 4.1 MM 7.6 MM 2229599-2 WASHER FLAT ISO7089 M4 A4 45066417 POLYETHYLENE BAG 80X120X0,12 5128566 INVERTER TANK CABLEKIT LABEL 2328759 JH4 INVERTER AUXILIARY CAN CABLE 99141914 CABL PL RD 1,27 25C AWG28 300V BL 5245017 CONNECTOR SUBD 25C RECEPTACLE IDC-FLAT CABLE, to be used with GE 99159614 part 99159614 CAPOT PL M 2P 45 SUBD 25C VC D11,7 91612905 MARKING LABEL WHT/TRANSP 25X19 BAND 2360764 JH4 HEATER CABLE 2362397-2 CABL 3C AWG16 600V SHIELDED GRAY 2186470-4 CONNEC 5,08/MSTBC 3C PLUG/CRIMP SOC 2187428 LOCATING FOR PLUG F TYPE CP-MSTB 2186471 CONTACT SERT MSTBC AWG16-14 F VRC 2186470-3 CONNEC 5,08/MSTBC 6C PLUG/CRIMP SOC 91612905 MARKING LABEL WHT/TRANSP 25X19 BAND 2108663-3 CLAMP,CLOSED/CABL D6.4X9.5 METAL M4 2380031-2 CLAMP,CLOSE LOOP, D6.35 W12.7 M6 ALU 46-208718P7 CLAMP CUSHIONED ID 0.625 LOOP TYPE TA MFG CORP TA713D10 46-208718P3 CLAMP, CUSHIONED, ID .375 LOOP TYPE TA MFG CORP TA713D6 99002494 SHRING TUBING BLACK D12,7/6,4 UL 2192410-2 SCREW HEXAGON SOCKET 4 MM 8 MM 2229255-3 WASHER LOCK - SPRING 4.1 MM 7.6 MM 2229599-2 WASHER FLAT ISO7089 M4 A4 2185581-3 SCREW HEXAGON SOCKET 6 MM 10 MM 2229255-5 WASHER LOCK - SPRING 6.1 MM 11.8 MM 2229599-4 WASHER FLAT ISO7089 M6 A4 45066417 POLYETHYLENE BAG 80X120X0,12 5128625 JH4 HEATER CABLE FASTENERS KIT LABEL 5117653 JH4 Inverter_Auxiliary Interface Packing Box 5132145 shortcircuit test tool 2325912 MPHVT JUNCTION BOX COVER V2 2325911 MPHVT JUNCTION BOX BASE V2 2284704 MPHVT-JUNCTION BOX CONTACT 99019996 NUT HEXAGON M8 BRASS 2225465-2 WAVED WASHER M8 8,4X17X0,8 CU-BE 2339500 SCREW SPECIAL HEAD 4 MM 24 MM 5129745 Court circuit cable for flat cable test 2360922 JH4 INVERTER AUXILIARY HARNESS 2266521-5 HV Tank (replaces 2266521-4 and 2266521-3 - backward compatable) used on LS 7.X, LS 5.X and LightSpeed RT. See Long Description for details 2266521-5 HV Tank (replaces 2266521-4 and 2266521-3 - backward compatable) used on LS 7.X, LS 5.X and LightSpeed RT. Dash Tanks includes the EMI Shielding needed for G-Das Part #: 2266521-5 Part Type: GP CONSUMABLES Part Weight: 0.00 LBR Repairable: No Returnable: No Hazardous Material: N Description: JEDI H4 MPHVTANK WITH SHIELDS FRU: Yes Status: Orderable Part #: 2266521-4 Part Type: GP CONSUMABLES Part Weight: -5499945.00 LBR Repairable: No Returnable: No Hazardous Material: N Description: JEDI H4 MPHVTANK WITH SHIELDS FRU: Yes Status: Orderable Part #: 2266521-3 Part Type: GP CONSUMABLE - RETURNABLE Part Weight: 200.84 LBR Repairable: No Returnable: Yes Hazardous Material: N Description: JEDI H4 MPHVTANK WITH SHIELDS FRU: Yes Status: Orderable Comments: added per ecr 2005924, as replacement for 2266521 and 266521-2. ms13452 040923 **If there is no Local Stock for the -3 part, you may order the -4 version which is backward compatible** ms0262 060815 *** 2ND OPINION NOTES *** Run the No-load KV test to verify HV tank is the error. 2281950-3 or 2281950-4 : JH4 INVERTER WITH SHIELDS used on LS 5.X (80/100), LS 7.X See Long Description for Details 2281950-3 Can also use 2281950-4 JH4 INVERTER WITH SHIELDS used on LS 5.X (80/100), LS 7.X Part #: 2281950- 3 Part Type: GP CONSUMABLE - RETURNABLE Part Weight: 0.00 LBR Repairable: No Returnable: Yes Hazardous Material: N Description: JH4 INVERTER WITH SHIELDS FRU: Yes Status: Orderable Comments: added per ecr 2005924, as replacement for 2281950 and 2281950-2. ms13452 040923 Set as Critical Part for Product CT_VCT, ms04278, 05Oct14 - If you receive an inverter as FRU (P/n 2281950, 2281950-2, 2281950-3) that must be installed to replace a defective inverter on site, check first Part number of PPC kV control board in this FRU: - if it is labelled 2351200-11 rev 001 this board needs to be replaced with the kV control board that is installed in the defective inverter: PPC board replacement, please refer to PPC FRU replacement procedure in service manual. - if it is not labelled 2351200-11 rev 001, the board installed on FRU is good: no modification is needed. Shawn Fox 3-24-05 Part #: 2281950 -4 Part Type: GP CONSUMABLES Part Weight: 0.00 LBRPart #: 2281950-4 Part Type: GP CONSUMABLES Part Weight: 0.00 LBR Repairable: No Returnable: No Hazardous Material: N Description: JH4 INVERTER WITH SHIELDS FRU: Yes Status: Orderable Comments: Added per ECR 2018129, THIS PART IS BACKWARD COMPATIBLE REPLACEMENT FOR 2281950-3, -2, & NO DASH. MS13452 050919 Repairable: No Returnable: No Hazardous Material: N Description: JH4 INVERTER WITH SHIELDS FRU: Yes Status: Orderable Comments: Added per ECR 2018129, THIS PART IS BACKWARD COMPATIBLE REPLACEMENT FOR 2281950-3, -2, & NO DASH. MS13452 050919
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.