Pular para o conteúdo principal
GE Healthcare · CTLightSpeedVCT

LightSpeed 7.x (VCT, VCT Select, Pro32)

Symptom

Customer reports damaged table cover. Customer reports damaged table cover

Applies to

Models
LightSpeed, VCT
Product
LightSpeed 7.x (VCT, VCT Select, Pro32) V40_H_V64_G_GTM V40_H_V64_G_GTL V40_H_V32_G_GTM V40_H_V32_G_GTL V40_H_H64_G_GTM V40_H_H64_G_GTL V40_H_HS64_G_G Product Name: LightSpeed 7.x (VCT, VCT Select, Pro32) Product photographs Method of remote or software identification - See attachment for a complete list of software commands and typical results. check_config swhwinfo “swhwinfo” will have the following new switches available with the VCT M4 and PF 1.5 M3 software release (software release deploying this “swhwinfo” capability is “06MW03.?”): · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) · -h or –help = Outputs complete details about all the available switches associated with swhwinfo · swhwinfo –c –m –o -da List of Supported Console Types GOC5 Will have a VDARC and VIG GOC6 Will have a VDIG List of softwares the product can run 09MW08.10 09MW08.11 08MW33.2 07MW18.4 06MW03.4 05MW31.6 FAQ's Table weight limit - Up to 500 lb. (227 kg) with ± .25 mm positional accuracy Tube type - D3194T D3193T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system. Done acording to template
Component
5140901-2 Rail cover 2000 LF N9 positioning GT see long description Part #: 5140901-2 Part Type: GP CONSUMABLES Part Weight: 0.00 KGM Repairable: No Returnable: No Hazardous Material: N Description: RAIL COVER 2000 LF N9 Positioning GT FRU: Yes Status: Orderable Parts Offered as: Current: 5140901-2 Harvested: Not Available Exchange: Not Available Comments: Per Kittyhawk RSPL, 212008898, 6/2/08. 5140902-2 Rail cover 2000 LR N9 Positioning GT see long description Part #: 5140902-2 Part Type: GP CONSUMABLES Part Weight: 0.00 KGM Repairable: No Returnable: No Hazardous Material: N Description: RAIL COVER 2000 LR N9 Positioning GT FRU: Yes Status: Orderable Parts Offered as: Current: 5140902-2 Harvested: Not Available Exchange: Not Available Comments: Per Kittyhawk RSPL, 212008898, 6/2/08. 5113617 TOP COVER SIDE BRKT 11 positioning G See Long Description for further details Part #: 5113617 Part Type: GP CONSUMABLES Part Weight: 0.00 LBR Repairable: No Returnable: No Hazardous Material: N Description: TOP COVER SIDE BRKT 11 positioning GT FRU: Yes Status: Orderable 5219979 CRADLE COVER ASSY WITH LOGO LABEL Positioning GT of FRU see long description 5219979 CRADLE COVER ASSY WITH LOGO LABEL Positioning GT of FRU Part #: 5219979 Part Type: GP CONSUMABLES Part Weight: 0.00 KGM Repairable: No Returnable: No Hazardous Material: N Description: CRADLE COVER ASSY WITH LOGO LABEL Positioning GT of FRU FRU: Yes Status: Orderable Parts Offered as: Current: 5219979 Harvested: Not Available Exchange: Not Available Comments: added per to ECR2044410 by sso#305010201 5127467-2 (replaces 5127467) TOP COVER SIDE L ASSY. See long description for details. 5127467-2 (replaces 5127467 ) TOP COVER SIDE L ASSY. 5127467 Part Type: GP CONSUMABLES Part Weight: 2.43 LBR Repairable: No Returnable: No Hazardous Material: No Description: TOP COVER SIDE L ASSY FRU: Yes Status: Orderable Comments: source pole/planner code revised per to Global Table transfer. Part #: 5127467-2 Part Type: GP CONSUMABLES Part Weight: 0.00 LBR Repairable: No Returnable: No Hazardous Material: N Description: TOP COVER SIDE L ASSY Positioning GT FRU: Yes Status: Orderable Comments: added per to ECR2052664 by sso#305010201 in Dec 10, 2008
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.

7-day free trial · no credit card required

Related GE Healthcare CT issues