GE Healthcare · CTLightSpeed2601151851272744134927175000260100042260100017

LightSpeed 5.X (60kW)

Symptom

Scan aborts with table cradle not moving during scan Scan aborts and table cradle not moving during scan with Error: 260134634 Tue Sep 27 16:15:22 2005 Error: 260134634 Host: tgp Process: tgp_subsys File: gtcb_cmc_profile.cxx Line: 537 Tue Sep 27 16:15:23 2005 Host : Table Sub-System Ermes # : 260134634 Exception Class : Secondary Severity : Pri/Soft File : gtcb_cmc_profile.cxx Line# : 537 Function : No System Function Reported Scan Type : None/Unknown Scan: 0/0/0 Cradle task received invalid corrected speed from cradle monitor task. received 284000 um/s expected 1 to 225000 um/s

Error message

Error: 260115185 Cradle velocity is out of tolerance Error. 260115185 Cradle velocity is out of tolerance cradle_position(um) : 1272744 target_position(um) : 1349271 velocity (um/s) : 75000 fpga status : 0x8104

Error: 260100042 Cradle was NOT ready See the long description for the full error code Tue May 17 16:02:03 2005 Error: 260100042 Host: tgp Process: tgp_subsys File: scHdwRdy.c Line: 70 Tue May 17 16:02:02 2005 Host : Table Gantry Processor Ermes # : 260100042 Exception Class : Soft Severity : Sec/Soft File : scHdwRdy.c Line# : 70 Function : No System Function Reported Scan Type : Scout Scan: 106/1/1 Cradle was NOT ready

Error: 260100017 Minimum required hardware NOT ready during exposure. See LD for more details Error: 260100017 Minimum required hardware NOT ready during exposure. Fri Aug 18 14:17:13 2006 Error: 260100017 Host: tgp Process: tgp_subsys File: scHdwRdy.c Line: 658 Fri Aug 18 14:17:12 2006 Host : Table Gantry Processor Ermes # : 260100017 Exception Class : Abort Severity : Primary File : scHdwRdy.c Line# : 658 Function : No System Function Reported Scan Type : Scout Scan: 6684/1/1 Minimum required hardware NOT ready during exposure. HW/OP/SW Error: Possible ha

Applies to

Models
LightSpeed
Product
LightSpeed 5.X (60kW) LightSpeed 5.X (60kW) ~ Use with MDAS or GDAS HP_P_G4 HP_P_G8 HP_P_G16 HP_P_M16 LightSpeed 5.X 60KW G-DAS16 with GRE Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.

7-day free trial · no credit card required

Related GE Healthcare CT issues