GE Healthcare · CTLightSpeedVCT26010721850053260100119

LightSpeed 7.x (VCT, VCT Select, Pro32)

Symptom

repeated Error message any time the Axial Drive Enable is disabled See long description Repeated Error message any time the Axial Drive Enable is disabled The symptom is invisible to the customera and will not stop scanning. It is just a nuissance messages in errorlogs. Service engineers are seeing it the errors in the error logs and wondering what they are, and if they are legitimate errors.

Error message

Error: 260107218 Gantry Drive Switch found DISABLED See LD for complete error Wed Jun 11 08:09:02 2008 Error: 260107218 Host: tgp Process: tgp_subsys File: amc_mon.c Line: 221 Wed Jun 11 08:09:02 2008 Host : Table Gantry Processor Ermes # : 260107218 Exception Class : Secondary Severity : Pri/Soft File : amc_mon.c Line# : 221 Function : AXIAL CONTROL : Axial Control Scan Type : Axial Scan: 50053/1/2 Gantry Drive Switch found DISABLED.

Error: 260100119 Gantry Service Switch is Enabled. see long description Wed Jul 23 19:35:09 2008 Error: 260100119 Host: tgp Process: tgp_subsys File: scGantryInMail.c Line: 1034 Wed Jul 23 19:35:07 2008 Host : Table Gantry Processor Ermes # : 260100119 Exception Class : Secondary Severity : Sec/Soft File : scGantryInMail.c Line# : 1034 Function : SYSTEM MONITORING : HVDC Monitor Scan Type : None/Unknown Scan: 0/0/0 Gantry Service Switch is Enabled. Tue Apr 28 12:38:07 2009 Error: 260100119 Host: tgp Process: tgp_subsys File: scGantryInMail.c Line: 1206 Tue Apr 28 12:38:06 2009 Host : Table Gantry Processor Ermes # : 260100119 Exception Class : Secondary Severity : Sec/Soft File : scGantryInMail.c Line# : 1206 Function : SYSTEM MONITORING : HVDC Monit

Applies to

Models
LightSpeed, VCT
Product
LightSpeed 7.x (VCT, VCT Select, Pro32) V40_H_V64_G_GTM V40_H_V64_G_GTL V40_H_V32_G_GTM V40_H_V32_G_GTL V40_H_H64_G_GTM V40_H_H64_G_GTL V40_H_HS64_G_G Product Name: LightSpeed 7.x (VCT, VCT Select, Pro32) Product photographs Method of remote or software identification - See attachment for a complete list of software commands and typical results. check_config swhwinfo “swhwinfo” will have the following new switches available with the VCT M4 and PF 1.5 M3 software release (software release deploying this “swhwinfo” capability is “06MW03.?”): · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) · -h or –help = Outputs complete details about all the available switches associated with swhwinfo · swhwinfo –c –m –o -da List of Supported Console Types GOC5 Will have a VDARC and VIG GOC6 Will have a VDIG List of softwares the product can run 09MW08.10 09MW08.11 08MW33.2 07MW18.4 06MW03.4 05MW31.6 FAQ's Table weight limit - Up to 500 lb. (227 kg) with ± .25 mm positional accuracy Tube type - D3194T D3193T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system. Done acording to template
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.