GE Healthcare · CTLightSpeedVCT2300081451241627901352896

LightSpeed 7.x (VCT, VCT Select, Pro32)

Symptom

Issue regarding zpos file in scan database See long description Review Notes: This issue has been seen on CT750, VCT Vision, and VCT Titan There is an issue regarding Zpos file in the scan database. This does not have real impact, but gave false impression that the scan data base was corrupted. Sometimes we saw such message in the gesyslog when the scanfilemgr was starting up. 1253178358 0 1 Thu Sep 17 09:05:58 2009 230008145 6 bay47 scanfilemgr sfm_server_api.c 703 Function: System Control : Scan Database Manager Scan Type: Not scanning Scan: 524/0/0 Extra characters detected in a scan file name. Actual name: s10a1_ZPos Expected name: s10a1 Directory: /usr/g/data_management/ex524.CT47.1253144479.67986 The file name may be corrected manually.EN 404SR 405 Actual the file was in the scan database can was correct. -rw-rw-rwx 1 root users 121488 Sep 16 23:52 s10a1_ZPos* -rw-rw-rwx 1 root users 10128860 Sep 16 23:52 s10a1*

Error message

Error: 230008145 Extra characters detected in a scan file name,The file name may be corrected manually. See long description for details Error 230008145 Extra characters detected in a scan file name,The file name may be corrected manually. Wed May 13 08:38:43 2009 230008145 6 ct99 scanfilemgr sfm_server_api.c 653 Function: System Control : Scan Database Manager Scan Type: Not scanning Scan: 636/0/0 Extra characters detected in a scan file name. Actual name: s5a1_EKG.csv Expected name: s5a1 Directory: /usr/g/data_management/ex636.CT99.1241627901.352896 The file name may be corrected manually. EN 405

Applies to

Models
LightSpeed, VCT
Product
LightSpeed 7.x (VCT, VCT Select, Pro32) V40_H_V64_G_GTM V40_H_V64_G_GTL V40_H_V32_G_GTM V40_H_V32_G_GTL V40_H_H64_G_GTM V40_H_H64_G_GTL V40_H_HS64_G_G Product Name: LightSpeed 7.x (VCT, VCT Select, Pro32) Product photographs Method of remote or software identification - See attachment for a complete list of software commands and typical results. check_config swhwinfo “swhwinfo” will have the following new switches available with the VCT M4 and PF 1.5 M3 software release (software release deploying this “swhwinfo” capability is “06MW03.?”): · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) · -h or –help = Outputs complete details about all the available switches associated with swhwinfo · swhwinfo –c –m –o -da List of Supported Console Types GOC5 Will have a VDARC and VIG GOC6 Will have a VDIG List of softwares the product can run 09MW08.10 09MW08.11 08MW33.2 07MW18.4 06MW03.4 05MW31.6 FAQ's Table weight limit - Up to 500 lb. (227 kg) with ± .25 mm positional accuracy Tube type - D3194T D3193T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system. Done acording to template
Software
10MW06.5 Titan for VCT (MUST HAVE SP1 or Higher) Systems running this version of software MUST also have SP1 or higher installed. Refer to FMI 25429 (SP1 release) 10MW06.5 Titan for VCT Delivered via new install or FMI 25425 Systems running this version of software MUST also have SP1 or higher installed. Refer to FMI 25429 (SP1 release)
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.