GE Healthcare · CTLightSpeed558911014433912821200002352200002372
Lightspeed 1.X - Octane
Symptom
System will not boot to or stay in applications. System will not boot or stay in applications
Error message
dksc0d1: [Alert] Media error : Write error (as seen in the Octane SYSLOG) See Long Description Example of a Octane disk drive WRITE Error, as seen in the /usr/adm/SYSLOG: cd /usr/adm more SYSLOG dksc0d1: <6>[Alert] Media error <6>: Write error (asc=0xc, asq=0x3)<6>, (data byte 20)<6>, Block #55891<6> (10144339)<6> Oct 4 17:04:33 6A:ct01 unix: dksc0d1: <6>[Alert] Media error <6>: Write error (asc=0xc, asq=0x3)<6>, (data byte 20)<6>, Block #55891<6> (10144339)<6> dks1d1s0: Media error: Unrecovered data block read error (asc=0x11, asq=0x0), (data byte 389), Block #7931 (12821) [filter /usr/in/klogpp failed: too slow] in /var/adm/SYSLOG See Long Description Error: 200002352 A HOST_SHUTDOWN was initiated by the death of scanmgr See Long Description for full error Tue Nov 23 17:26:47 2004 Error: 200002352 Host: srct Process: cupMonitor File: ssProcStop.c Line: 1065 A HOST_SHUTDOWN was initiated by the death of scanmgr With 06MW03.X software this is listed as: Fri Oct 6 19:02:31 2006 Error: 200002352 Host: dominct Process: cupMonitor File: ssProcStop.c Line: 766 A HOST_SHUTDOWN was initiatied by the unexpected termination of scanmgr. Error: 200002372 The process scanmgr took too long t
Applies to
- Models
- LightSpeed
- Product
- Lightspeed 1.X - Octane 10.5_2.8.2I_H1.3M4 10.4.1_2.8.2I_H1.3M4 - obsolete Lightspeed 1.X - Octane Method of visual identification Method of remote or software identification - See attachment below for a complete list of software commands and typical results. check_config showprods|grep Apps note: if check_config does not work then the software is not up to date with all FMI's. Check FMI history and verify that all patches have been loaded since last software reload. Ref FMI 25269 List of Supported Console Types Octane with Pegasus Recon hardware. may have an 02 SBC - Run df -k to see if the sbc is partitioned. List of softwares the product can run 10.5_2.8.2I_H1.3M4 10.4.1_2.8.2I_H1.3M4 - obsolete FAQ's Table weight limit - Up to 400 lb. (180 kg) with ± .25 mm positional accuracy. 450Ib (205 kg) max weight Tube type - D3176T Current production details - See Technical Reference Manual found on the Common Document Library Tips and workarounds, where to find it - Common Document Library(CDL) . Search for the latest FMI software release. In the furnished materials will be the list of various manuals with part numbers for the various languages. Example: English versions 2211223-100 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required