GE Healthcare · CTLightSpeedVCT230023002244640244634244540
Can not do tube warmup after cycling main power
Symptom
Can not do a tube warmup after cycling main power and rebooting. Can not do a tube warmup after cycling main power and rebooting
Error message
Error : 230023002 Scanner Hardware is not ready or unavailable See LD for more info Fri Jun 10 08:22:33 2005 230023002 4 cr_ct_01 scanUtilsRx DetailedCalUtils.c 1160 FAILED to execute the Scan Request. Possible Reasons: Scanner Hardware is not ready or unavailable. Please verify and try again. *** Laser indicator flashing on the Gantry Display board – this indicates the system has lost communication with the ORP board. *** Additional error info: Error: 244640 HARD RESET through serial connection failed. some controllers(TGP, ORP) do not response to ping. Error: 244634 Immediate Request cannot be honored since the firmware is in the DOWN state Fri Jun 10 08:22:13 2005 230023002 host: cr_ct_01 process: scanUtilsRx DetailedCalUtils.c 1160 FAILED to execute the Scan Request. Possible Reasons: Scanner Hardware is not ready or unavailable. Please verify and try again. Fri Jun 10 08:22:33 2005 230023002 4 cr_ct_01 scanUtilsRx DetailedCalUtils.c 1160 FAILED to execute the Scan Request. Possible Reasons: Scanner Hardware is not ready or unavailable. Please verify and try again. Fri Jun 10 08:22:35 2005 244640 2 cr_ct_01 fwmgr fwmgr_fw_if.cxx 369 HARD RESET through serial connection failed.
Applies to
- Models
- LightSpeed, VCT
- Product
- LightSpeed 7.x (VCT, VCT Select, Pro32) V40_H_V64_G_GTM V40_H_V64_G_GTL V40_H_V32_G_GTM V40_H_V32_G_GTL V40_H_H64_G_GTM V40_H_H64_G_GTL V40_H_HS64_G_G Product Name: LightSpeed 7.x (VCT, VCT Select, Pro32) Product photographs Method of remote or software identification - See attachment for a complete list of software commands and typical results. check_config swhwinfo “swhwinfo” will have the following new switches available with the VCT M4 and PF 1.5 M3 software release (software release deploying this “swhwinfo” capability is “06MW03.?”): · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) · -h or –help = Outputs complete details about all the available switches associated with swhwinfo · swhwinfo –c –m –o -da List of Supported Console Types GOC5 Will have a VDARC and VIG GOC6 Will have a VDIG List of softwares the product can run 09MW08.10 09MW08.11 08MW33.2 07MW18.4 06MW03.4 05MW31.6 FAQ's Table weight limit - Up to 500 lb. (227 kg) with ± .25 mm positional accuracy Tube type - D3194T D3193T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system. Done acording to template
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required