Symptom

Intermittent scan aborts with washed out images. See LD for a sample error stream for this issue. Intermittent scan aborts with washed out looking images. FULL error stream: Thu Jan 4 10:34:16 2007 Error: 260101023 Host: orp Process: orp_subsys File: rcib_erlog.c Line: 463 Thu Jan 4 10:34:14 2007 Host : Collimator Ermes # : 260101023 Exception Class : Abort Severity : Primary File : rcib_erlog.c Line# : 463 Function : No System Function Reported Scan Type : Helical Scan: 3123/200/1 The CCB has notified the system of an error condition which prevents scanning. See log for further information:^C Error message code: 260003164 Notification level: 5 Sequence number: 2 Thu Jan 4 10:34:16 2007 Error: 260003149 Host: orp Process: orp_subsys File: cfg_cam.c Line: 191 Thu Jan 4 10:34:14 2007 Host : Collimator Ermes # : 260003149 Exception Class : Secondary Severity : Pri/Soft File : cfg_cam.c Line# : 191 Function : No System Function Reported Scan Type : Helical Scan: 3123/200/1 Illegal distance for CAM A encoder count conversion. Requested distance: -288 micrometers Thu Jan 4 10:34:16 2007 Error: 245043 Host: diag_oc0 Process: scanmgr File: scanmgr_events.cxx Line: 2309 Function: System Control : Scan Control Scan Type: Helical Scan: 0/0/0 Scan Seq Id: 437000 Scanning System Aborted Scanning Thu Jan 4 10:34:16 2007 Error: 245213 Host: diag_oc0 Process: scanmgr File: scanmgr_events.cxx Line: 2317 Function: System Control : Scan Control Scan Type: Helical Scan: 0/0/0 Scan Seq Id: 437000 Scan was Paused/Aborted by Firmware Thu Jan 4 10:34:16 2007 Error: 245180 Host: diag_oc0 Process: scanmgr File: scan_complete.cxx Line: 368 Function: System Control : Scan Control Scan Type: Helical Scan: 0/0/0 Scan Seq Id: 437000 System aborted Helical scanning. Views expected 31827 Views collected 20813 Thu Jan 4 10:34:16 2007 Error: 260003164 Host: orp Process: orp_subsys File: aperture_z_axis.c Line: 230 Thu Jan 4 10:34:14 2007 Host : Collimator Ermes # : 260003164 Exception Class : Abort Severity : Primary File : aperture_z_axis.c Line# : 230 Function : No System Function Reported Scan Type : None/Unknown Scan: 3123/200/0 A Z-Axis Update Contained a Move That Is Invalid For CAM A. Position : -288 Sequence Number: 166 Thu Jan 4 10:34:24 2007 Error: 245277 Host: diag_oc0 Process: scanmgr File: scanmgr_events.cxx Line: 2261 Function: System Control : Scan Control Scan Type: Helical Scan: 0/0/0 Scan Seq Id: 438000 Operator Paused Scanning (via Host Request) Thu Jan 4 10:34:40 2007 Error: 245277 Host: diag_oc0 Process: scanmgr File: scanmgr_events.cxx Line: 2261 Function: System Control : Scan Control Scan Type: Helical Scan: 0/0/0 Scan Seq Id: 439000 Operator Paused Scanning (via Host Request) Thu Jan 4 10:34:44 2007 Error: 290012000 Host: ig1 Process: image_generation File: IgManager.cpp Line: 4041 View corrections were applied in view 2734. exam/series/scan = 3123/2/1 Thu Jan 4 10:34:44 2007 Error: 290012001 Host: ig1 Process: image_generation File: IgManager.cpp Line: 4057 View correction for view 2458 from views 2457, 2464 There are more than 5 consecutive bad views - no correction applied exam/series/scan = 3123/2/1 Thu Jan 4 10:34:44 2007 Error: 290009001 Host: darc Process: recon_control File: ImageSetRequest.cxx Line: 3791 The scanfile does not have enough views to make requested images. exam/series/scan = 3123/2/1 expected number of images = 215 created number of images = 138 max number of images = 138 scan completed = 1 IG node = 1 Thu Jan 4 10:36:59 2007 Error: 0 Thu Jan 4 10:39:34 2007 Error: 200109110 Host: diag_oc0 Process: scanRx File: UIRx.cxx Line: 10400 Function: Data Acquisition : OC Processing End: Prospective Exam: 3123: Protocol: 6.2 S eries: 1 : Scans: 2 : Images: 2 (Scout) S eries: 2 : Scans: 1 : Images: 138 : PMRSeries(0) : SPScans: 3 S eries: 3 : Scans: 1 : Images: 229 : PMRSeries(0) F ULL error stream: T Thu Jan 4 10:34:16 2007 Error: 260101023 Host: orp Process: orp_subsys File: rcib_erlog.c Line: 463 Thu Jan 4 10:34:14 2007 Host : Collimator Ermes # : 260101023 Exception Class : Abort Severity : Primary File : rcib_erlog.c Line# : 463 Function : No System Function Reported Scan Type : Helical Scan: 3123/200/1 The CCB has notified the system of an error condition which prevents scanning. See log for further information:^C Error message code: 260003164 Notification level: 5 Sequence number: 2 Thu Jan 4 10:34:16 2007 Error: 260003149 Host: orp Process: orp_subsys File: cfg_cam.c Line: 191 Thu Jan 4 10:34:14 2007 Host : Collimator Ermes # : 260003149 Exception Class : Secondary Severity : Pri/Soft File : cfg_cam.c Line# : 191 Function : No System Function Reported Scan Type : Helical Scan: 3123/200/1 Illegal distance for CAM A encoder count conversion. Requested distance: -288 micrometers Thu Jan 4 10:34:16 2007 Error: 245043 Host: diag_oc0 Process: scanmgr File: scanmgr_events.cxx Line: 2309 Function: System Control : Scan Control Scan Type: Helical Scan: 0/0/0 Scan Seq Id: 437000 Scanning System Aborted Scanning Thu Jan 4 10:34:16 2007 Error: 245213 Host: diag_oc0 Process: scanmgr File: scanmgr_events.cxx Line: 2317 Function: System Control : Scan Control Scan Type: Helical Scan: 0/0/0 Scan Seq Id: 437000 Scan was Paused/Aborted by Firmware Thu Jan 4 10:34:16 2007 Error: 245180 Host: diag_oc0 Process: scanmgr File: scan_complete.cxx Line: 368 Function: System Control : Scan Control Scan Type: Helical Scan: 0/0/0 Scan Seq Id: 437000 System aborted Helical scanning. Views expected 31827 Views collected 20813 Thu Jan 4 10:34:16 2007 Error: 260003164 Host: orp Process: orp_subsys File: aperture_z_axis.c Line: 230 Thu Jan 4 10:34:14 2007 Host : Collimator Ermes # : 260003164 Exception Class : Abort Severity : Primary File : aperture_z_axis.c Line# : 230 Function : No System Function Reported Scan Type : None/Unknown Scan: 3123/200/0 A Z-Axis Update Contained a Move That Is Invalid For CAM A. Position : -288 Sequence Number: 166 Thu Jan 4 10:34:24 2007 Error: 245277 Host: diag_oc0 Process: scanmgr File: scanmgr_events.cxx Line: 2261 Function: System Control : Scan Control Scan Type: Helical Scan: 0/0/0 Scan Seq Id: 438000 Operator Paused Scanning (via Host Request) Thu Jan 4 10:34:40 2007 Error: 245277 Host: diag_oc0 Process: scanmgr File: scanmgr_events.cxx Line: 2261 Function: System Control : Scan Control Scan Type: Helical Scan: 0/0/0 Scan Seq Id: 439000 Operator Paused Scanning (via Host Request) Thu Jan 4 10:34:44 2007 Error: 290012000 Host: ig1 Process: image_generation File: IgManager.cpp Line: 4041 View corrections were applied in view 2734. exam/series/scan = 3123/2/1 Thu Jan 4 10:34:44 2007 Error: 290012001 Host: ig1 Process: image_generation File: IgManager.cpp Line: 4057 View correction for view 2458 from views 2457, 2464 There are more than 5 consecutive bad views - no correction applied exam/series/scan = 3123/2/1 Thu Jan 4 10:34:44 2007 Error: 290009001 Host: darc Process: recon_control File: ImageSetRequest.cxx Line: 3791 The scanfile does not have enough views to make requested images. exam/series/scan = 3123/2/1 expected number of images = 215 created number of images = 138 max number of images = 138 scan completed = 1 IG node = 1 Thu Jan 4 10:36:59 2007 Error: 0 Thu Jan 4 10:39:34 2007 Error: 200109110 Host: diag_oc0 Process: scanRx File: UIRx.cxx Line: 10400 Function: Data Acquisition : OC Processing End: Prospective Exam: 3123 : Protocol: 6.2 Series: 1 : Scans: 2 : Images: 2 (Scout)

Error message

Error: 260003141 Filter homing problem. See the Long Description for the full error code Fri Mar 4 21:22:12 2005 Host : Collimator Ermes # : 260003141 Exception Class : Abort Severity : Primary File : filter_home.c Line# : 147 Function : No System Function Reported Scan Type : None/Unknown Scan: 13155/1/0 Filter homing problem.

Error: 260003158 The Filter Home Flag Has Moved Since The Last Reference See long description for full error Fri Feb 17 17:56:41 2006 Error: 260003158 Host: HSC Process: CCB Firmware File: filter_home.c Line: 193 Function: XRAY GENERATION : Xray Collimation and Filtration Scan: 8650/2/0 Type: None/Unknown Exception Level: Sec/Soft Time: 17:56:41:390 Log Series: 564 The Filter Home Flag Has Moved Since The Last Reference. Possible Causes: Filter Home Switch, Filter Encoder, Filter Encoder Set Screw. Difference: 360 degrees

Applies to

Models
LightSpeed
Product
LightSpeed 4.X - GRE See Long Description for detailed information - H2_P_M16 Product Name: LightSpeed 4.X with GRE Product Photographs GE HEALTHCARE Method of remote or software identification - See attachment below for a complete list of software commands and typical results 1. check_config 2 . swhwinfo “swhwinfo” will have the following switches: · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) -h or –help = Outputs complete details about all the available switches associated with swhwinfo swhwinfo –c –m –o -da List of Supported Console types: GOC3 (GRE) GOC4 (GRE) List of software the product can run: 07MW11.10 SP2.0, SP3.0, SP3.1 FAQ's Table weight limit - 180 kg (400 lbs) normal operation - 205 kg (450 lbs) maximum allowed with decreased accuracy Tube type - D3186T D3186T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
Component
5140001-3 (replaces 5140001-2) Helios 3 collimator with notched filler bar and rating plate (used on 1.X-4.X) See Long Description for more info Part #: 5140001-3 Part Type: GP REPAIRABLES Part Weight: 115.00 LBR Repairable: Yes Returnable: Yes Hazardous Material: N Description: helios 3 collimator with notched filler bar and rating plate FRU: Yes Status: Orderable Comments: ** FE Assist ** 1.x 2.x 3.x 4.x started with Ultras added minor quality improvements to the dash 2 and is backwards compatible (12/6/06 212001261) Part #: 5140001-2 Part Type: GP REPAIRABLES Part Weight: 0.00 LBR Repairable: Yes Returnable: Yes Hazardous Material: N Description: helios 2 collimator with notched filler bar and rating plate FRU: Yes Status: Orderable Comments: This part is replacement for 2214768-2, please do not use stock of 2214768-2. ms13452 050516 Can use the 5140001-3 if no Stock of the -2 (9/26/05 212001261)
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.

7-day free trial · no credit card required