LightSpeed 7.x (VCT, VCT Select, Pro32)

Symptom

Scanner Hardware Stopped Scan. Scanner Hardware Stopped Scan

Error message

Error: 260125041 Uncommanded Table Motion with the Elevation drive. See long description for a sample error message. Thu Jan 28 08:29:19 2010 Error: 260125041 Host: tgp Process: tgp subsys File: ta callback gt.c Line: 504 Thu Jan 28 08:29:19 2010 Host : Table Gantry Processor Ermes # : 260125041 Exception Class : Abort Severity : Primary File : ta callback gt.c Line# : 504 Function : No System Function Reported Scan Type : Axial Scan: 1212/2/9 Uncommanded Table Motion with the Elevation drive. Current pos:848952 um Last stop pos:845750 um Tolerance:3000 um Time since last stop:124190 ms Last target pos:4294907296 um Hardware status:0 Another drive (Elevation or Cradle) pos:445950 um

Applies to

Models
LightSpeed, VCT
Product
LightSpeed 7.x (VCT, VCT Select, Pro32) V40_H_V64_G_GTM V40_H_V64_G_GTL V40_H_V32_G_GTM V40_H_V32_G_GTL V40_H_H64_G_GTM V40_H_H64_G_GTL V40_H_HS64_G_G Product Name: LightSpeed 7.x (VCT, VCT Select, Pro32) Product photographs Method of remote or software identification - See attachment for a complete list of software commands and typical results. check_config swhwinfo “swhwinfo” will have the following new switches available with the VCT M4 and PF 1.5 M3 software release (software release deploying this “swhwinfo” capability is “06MW03.?”): · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) · -h or –help = Outputs complete details about all the available switches associated with swhwinfo · swhwinfo –c –m –o -da List of Supported Console Types GOC5 Will have a VDARC and VIG GOC6 Will have a VDIG List of softwares the product can run 09MW08.10 09MW08.11 08MW33.2 07MW18.4 06MW03.4 05MW31.6 FAQ's Table weight limit - Up to 500 lb. (227 kg) with ± .25 mm positional accuracy Tube type - D3194T D3193T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system. Done acording to template
Component
5127284-3 (replaces 5127284) PROPORTIOAL VALVE ASSY Positoning GT - FRU yes - this assembly contains two proportional valves. See Long Description for details and picture: Part #: 5127284-3Part Type: GP CONSUMABLES Part Weight: 0.00 LBRRepairable: NoReturnable: NoHazardous Material: NDescription: PROPORTIOAL VALVE ASSY Positoning GTFRU: YesStatus: Orderable Comments: added per to ECO2079401 by sso#305010201 in Jun 8, 2009 Part #: 5127284 Part Type: GP CONSUMABLES Part Weight: 2.18 LBR Repairable: No Returnable: No Hazardous Material: N Description: PROPORTIOAL VALVE ASSY Positoning GT FRU: Yes Status: Orderable Comments: Not Available This part is actually an assembly - the assembly contains two proportional valves and wire cable harness assembled/wired together. GT
Area
CT

Full cause & step-by-step resolution