GE Healthcare · CTLightSpeed182825182826182888
LightSpeed 3.X (Ultra, Plus, QX/i) - Octane
Symptom
Gantry Control Panel Flashing "ERR". Gantry Control Panel Flashing "ERR"
Error message
Error: 182825 Communication Problems with the GANTRY CONTROL See Long Description for full error Tue Dec 1 17:17:45 2009 Error: 182825 Host: ETC Process: Gantry Display File: gd_tnc_driver.c Line: 471 Function: No System Function Reported Scan: 0/0/0 Type: None/Unknown Exception Level: Pri/Soft Time: 17:17:39:290 Log Series: 11 HW/SW error: Communication Problems with the GANTRY CONTROL. Number of Communication Timeout errors: 3. Number of NACK''s errors: 0. Number of DUART errors: 0. Numver of Checksum errors: 0 Error: 182826 Communication Error: Communication Packet with the GANTRY CONTROL See Long Description for full error Tue Dec 1 17:17:45 2009 Error: 182826 Host: ETC Process: Gantry Display File: gd_tnc_driver.c Line: 477 Function: No System Function Reported Scan: 0/0/0 Type: None/Unknown Exception Level: Pri/Soft Time: 17:17:39:290 Log Series: 12 Communication Error: Communication Packet with the GANTRY CONTROL. Message Code: 18. (Data = 0x0, 0x3d, 0x29, 0x0). Error: 182888 No Gantry Controls Were Detected By the TNC See long description Thu Mar 4 09:22:43 2010 Error: 182888 Host: ETC Process: Gantry Display File: gd_tnc_init.c Line: 822 Function: No System Function Repo
Applies to
- Models
- LightSpeed
- Product
- LightSpeed 3.X (Ultra, Plus, QX/i) - Octane Always 4 or 8 slice MDAS 308i.2_H3.1M5 LightSpeed 3.X - Octane Method of visual identification Method of remote or software identification - See attachment below for a complete list of software commands and typical results. check_config List of Supported Console Types Octane with Pegasus Recon hardware. List of softwares the product can run 308I.2_H3.1M5 305.4_H3.1M4 - obsolete 303.1_H3M4 - obsolete FAQ's Table weight limit - Up to 400 lb. (180 kg) with ± .25 mm positional accuracy. 450Ib (205 kg) max weight Tube type - D3186T Current production details - See Technical Reference Manual found on the Common Document Library Tips and workarounds, where to find it - Common Document Library(CDL) . Search for the latest FMI software release. In the furnished materials will be the list of various manuals with part numbers for the various languages. Example: English versions 2211223-100 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Component
- 2372485 ETC IF (Interface or TNC Bd.) Replaces 2229871 See long description for details 2372485 ETC IF (Interface or TNC Bd.) Replaces 2229871 Part #: 2372485 Part Type: GP CONSUMABLE - RETURNABLE Part Weight: 0.00 LBR Repairable: No Returnable: Yes Hazardous Material: N Description: ETC INTERFACE W/ AZ60A FRU: Yes Status: Orderable Comments: FLS - ETC INTERFACE W/ AZ60A. ADDED PER PCN 220857. REPLACES P/N 2229871. USE UP EXISTING STK. MS20544 5/1/03. ONE USE LIGHTSPEED PLUS VC:611695-SCI, RAPID CITY, SD CONTROL PCB 46-264368G3
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.