GE Healthcare · CTLightSpeedVCT26010016150033245213107000601000245047
LightSpeed 7.x (VCT, VCT Select, Pro32)
Symptom
DCB aborted the scan due to an Disruption in Das view Triggers across the Slip Rings. DCB aborted the scan due to an interruption of Das views across the Slip Ring
Error message
Error: 260100161 DAS Ready-For-Views message received before offset triggers were stopped See Long Description for complete error Thu Feb 11 20:00:21 2010 260100161 2 tgp tgp_subsys scTrigSeqActions.c 2128 Thu Feb 11 20:00:20 2010 Host : Table Gantry Processor Ermes # : 260100161 Exception Class : Abort Severity : Primary File : scTrigSeqActions.c Line# : 2128 Function : No System Function Reported Scan Type : Axial Scan: 50033/1/2 DAS Ready-For-Views message received before offset triggers were stopped. HW/SW Error: Probable problem with das trigger or das view hardware or cables. Possible sofware sequencing problem. (Das Rcv Triggers:2 (N/A = -1)). Error: 245213 Scan was Paused/Aborted by Firmware (or the host) This is mostly a generic error See LD for error examples Error 245213 is a generic error caused by scan file manager Wed Apr 27 01:01:26 2005 Error: 245213 Host: ls16er Process: scanmgr File: scanmgr_events.cxx Line: 1617 Function: System Control : Scan Control Scan Type: Cine Scan: 0/0/0 Scan Seq Id: 107000 Scan was Paused/Aborted by Firmware You may also see another form of this error. Thu May 12 17:43:37 2005 Error: 245213 Host: rrmcct16 Process: scanmgr File: scanmgr_
Applies to
- Models
- LightSpeed, VCT
- Product
- LightSpeed 7.x (VCT, VCT Select, Pro32) V40_H_V64_G_GTM V40_H_V64_G_GTL V40_H_V32_G_GTM V40_H_V32_G_GTL V40_H_H64_G_GTM V40_H_H64_G_GTL V40_H_HS64_G_G Product Name: LightSpeed 7.x (VCT, VCT Select, Pro32) Product photographs Method of remote or software identification - See attachment for a complete list of software commands and typical results. check_config swhwinfo “swhwinfo” will have the following new switches available with the VCT M4 and PF 1.5 M3 software release (software release deploying this “swhwinfo” capability is “06MW03.?”): · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) · -h or –help = Outputs complete details about all the available switches associated with swhwinfo · swhwinfo –c –m –o -da List of Supported Console Types GOC5 Will have a VDARC and VIG GOC6 Will have a VDIG List of softwares the product can run 09MW08.10 09MW08.11 08MW33.2 07MW18.4 06MW03.4 05MW31.6 FAQ's Table weight limit - Up to 500 lb. (227 kg) with ± .25 mm positional accuracy Tube type - D3194T D3193T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system. Done acording to template
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required