GE Healthcare · CTLightSpeedVCT26013481310000260134812260134802398728100000
LightSpeed 7.x (VCT, VCT Select, Pro32)
Symptom
Cradle / IMS on GT1700 / GT2000 would not advance from home and makes grinding noise. See Long Description for more details and sound. Cradle / IMS on GT1700 / GT2000 would not advance from home and makes grinding noise This problem happen after moving a large patient off of the table, or after physically moving the IMS to it’s mechanical out of gantry limit (home). Attachment is the sound the table makes when the cradle move button is pushed. The button was pressed 2 times (2 sounds)
Error message
Error: 260134813 IMS absolute encoder communication error occur. See long description Sun Feb 14 16:22:51 2010 Error: 260134813 Host: tgp Process: tgp_subsys File: gtcb_imc_drv_req.cxx Line: 516 Sun Feb 14 16:22:51 2010 Host : Table Sub-System Ermes # : 260134813 Exception Class : Secondary Severity : Pri/Soft File : gtcb_imc_drv_req.cxx Line# : 516 Function : No System Function Reported Scan Type : None/Unknown Scan: 0/0/0 IMS absolute encoder communication error occur. Position is -10000 um. Error: 260134812 IMS absolute encoder warning See long description Sun Feb 14 16:22:51 2010 Error: 260134812 Host: tgp Process: tgp_subsys File: gtcb_imc_drv_req.cxx Line: 510 Sun Feb 14 16:22:51 2010 Host : Table Sub-System Ermes # : 260134812 Exception Class : Secondary Severity : Pri/Soft File : gtcb_imc_drv_req.cxx Line# : 510 Function : No System Function Reported Scan Type : None/Unknown Scan: 0/0/0 IMS absolute encoder warning occur. Position is -10000 um. Error: 260134802 IMS position is out of tolerance. See Long Description error messages Thu Oct 20 08:01:13 2005 Error: 260134802 Host: tgp Process: tgp subsys File: gtcb movechk.cxx Line: 581 Thu Oct 20 08:01:13 2005 Host : Table S
Applies to
- Models
- LightSpeed, VCT
- Product
- LightSpeed 7.x (VCT, VCT Select, Pro32) V40_H_V64_G_GTM V40_H_V64_G_GTL V40_H_V32_G_GTM V40_H_V32_G_GTL V40_H_H64_G_GTM V40_H_H64_G_GTL V40_H_HS64_G_G Product Name: LightSpeed 7.x (VCT, VCT Select, Pro32) Product photographs Method of remote or software identification - See attachment for a complete list of software commands and typical results. check_config swhwinfo “swhwinfo” will have the following new switches available with the VCT M4 and PF 1.5 M3 software release (software release deploying this “swhwinfo” capability is “06MW03.?”): · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) · -h or –help = Outputs complete details about all the available switches associated with swhwinfo · swhwinfo –c –m –o -da List of Supported Console Types GOC5 Will have a VDARC and VIG GOC6 Will have a VDIG List of softwares the product can run 09MW08.10 09MW08.11 08MW33.2 07MW18.4 06MW03.4 05MW31.6 FAQ's Table weight limit - Up to 500 lb. (227 kg) with ± .25 mm positional accuracy Tube type - D3194T D3193T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system. Done acording to template
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required