GE Healthcare · CTLightSpeed

LightSpeed 4.X - GRE

Symptom

A loud pop or bang was heard from the gantry. The customer was unable to, complete the scan or scan any more patients. A loud pop or bang was heard from the gantry. The customer was unable to, complete the scan or scan any more patients

Applies to

Models
LightSpeed
Product
LightSpeed 4.X - GRE See Long Description for detailed information - H2_P_M16 Product Name: LightSpeed 4.X with GRE Product Photographs GE HEALTHCARE Method of remote or software identification - See attachment below for a complete list of software commands and typical results 1. check_config 2 . swhwinfo “swhwinfo” will have the following switches: · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) -h or –help = Outputs complete details about all the available switches associated with swhwinfo swhwinfo –c –m –o -da List of Supported Console types: GOC3 (GRE) GOC4 (GRE) List of software the product can run: 07MW11.10 SP2.0, SP3.0, SP3.1 FAQ's Table weight limit - 180 kg (400 lbs) normal operation - 205 kg (450 lbs) maximum allowed with decreased accuracy Tube type - D3186T D3186T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
Component
2254361 BRUSH BLOCK W/ POWER & SIG TIP HOLDERS ONLY See Long Description for details 2254361 Brush Block with Power and Signal Tip Holders Only. This does not include the actual brushes which must be ordered separately. Part #: 2254361 Part Type: GP CONSUMABLES Part Weight: -22 LBR Repairable: No Returnable: No Hazardous Material: N Description: BRUSH BLOCK W/ PWR & SIG TIP HOLDERS FRU: Yes Status: Orderable Comments: FLS - BRUSH BLOCK FOR HINO PROSPEED AND H2 GELS - CSO 303081 030327 ROUILES R13655054001,BRUSH BLOCK WITH HOLDER 2245480 SIGNAL BRUSH TIP SET FOR HSDCD See Long Description for details Part #: 2245480 Part Type: GP CONSUMABLES Part Weight: 10.91 LBR Repairable: No Returnable: No Hazardous Material: N Description: SIGNAL BRUSH TIP SET FOR HSDCD FRU: Yes Status: Orderable Comments: FLS - SIGNAL BRUSH TIP SET FOR HSDCDHINO LXI,DXI,FXI,ZXI/CTE MS08992 3/7/00 FE NOTE: THIS KIT CONTAINS 40 BRUSHES WITH CAPS. MS03185 11/02/01 DO NOT DISCOUNT - PER SHAKUN 32 PCS 2253677 MAT'L CA40 TIPS 8 PCS 2253678 MAT'L CAG TIPS 40 PCS 2253686 BRUSH CAPS ON PROMOTON THROUGH JUNE 30, 2004-DO NOT CHANGE PRICE PER SHAWN (MAYND) GELS - 46-296221P15 80A 600V Fuse See Long Description for details Part #: 46-296221P15 Part Type: GP CONSUMABLES Part Weight: 0.13 LBR Repairable: No Returnable: No Hazardous Material: N Description: BUSSMANN KBC80 FRU: Yes Status: Orderable Comments: FLS - CLASS 1 FRU. PDV BUSSMANN KBC80 80A, 600V THERE ARE 3 OF THESE FUSES IN FUSE KIT 2218570 - MS4751 8/01 PRICE CHANGE PER BRIAN NAGLE 4/98 FLS - FE ASSIST: IN ORDER TO INCREAS INCREASE REVENUE GLOBAL PARTS HAS CREATED A PROGRAM TO HARVEST PARTS FROM RENEWABLE RESOURCRESOURCES. THESE PARTS OFFER DIRECT SAVINGS TO THE BUSINESSAND THE FIELD. ORDER THE U PART WHEN AVAILABLE. IF NO U USED PARTS ARE AVAILABLE CARES WILL CHANGE THE ORDER TOA NEW PART.
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.