LightSpeed 7.x (VCT, VCT Select, Pro32)

Symptom

Customer calls with severe noise on the ECG trace of their patient. See Long Description for ECG example Customer calls with severe noise on the ECG trace of their patient.

Error message

Error: 260100076 The current heartrate is outside scannable limits. Heart Rate: 244 See long description Mon Oct 26 12:23:36 2009 Error: 260100076 Host: tgp Process: tgp_subsys File: scExternalGate.c Line: 1478 Mon Oct 26 12:23:35 2009 Host : Table Gantry Processor Ermes # : 260100076 Exception Class : Abort Severity : Primary File : scExternalGate.c Line# : 1478 Function : No System Function Reported Scan Type : Axial Scan: 4146/4/3 The current heart rate is outside scannable limits. Heart Rate: 244

Error: 245180 System aborted Xray-on Static scanning. Wed May 12 13:54:02 2004 Error: 245180 Host: ctpro100 Process: scanmgr File: scan_complete.cxx Line: 313 Function: System Control : Scan Control Scan Type: Xray-on Static Scan: 0/0/0 Scan Seq Id: 1000 System aborted Xray-on Static scanning. Views expected 992 Views collected 0 an updated version of this error Wed Feb 9 14:53:22 2011 Error: 245180 Host: ct04 Process: scanmgr Function: System Control : Scan Control Scan Type: Helical Scan: 0/0/0 System aborted Helical scanning. Views expected 8762 Views collected 5555

Applies to

Models
LightSpeed, VCT
Product
LightSpeed 7.x (VCT, VCT Select, Pro32) V40_H_V64_G_GTM V40_H_V64_G_GTL V40_H_V32_G_GTM V40_H_V32_G_GTL V40_H_H64_G_GTM V40_H_H64_G_GTL V40_H_HS64_G_G Product Name: LightSpeed 7.x (VCT, VCT Select, Pro32) Product photographs Method of remote or software identification - See attachment for a complete list of software commands and typical results. check_config swhwinfo “swhwinfo” will have the following new switches available with the VCT M4 and PF 1.5 M3 software release (software release deploying this “swhwinfo” capability is “06MW03.?”): · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) · -h or –help = Outputs complete details about all the available switches associated with swhwinfo · swhwinfo –c –m –o -da List of Supported Console Types GOC5 Will have a VDARC and VIG GOC6 Will have a VDIG List of softwares the product can run 09MW08.10 09MW08.11 08MW33.2 07MW18.4 06MW03.4 05MW31.6 FAQ's Table weight limit - Up to 500 lb. (227 kg) with ± .25 mm positional accuracy Tube type - D3194T D3193T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system. Done acording to template
Component
5112819-3 ECG, LOW-NOISE, LEAD WIRES, 24in LONG, SET OF 3 see LD 5112819-3 ECG, LOW-NOISE, LEAD WIRES , 24in LONG, SET OF 3 Part #: 5112819-3 Part Type: GP CONSUMABLES Part Weight: 0.00 LBR Repairable: No Returnable: No Hazardous Material: N Description: ECG, LOW-NOISE, LEAD WIRES, 24in LONG, SET OF 3 FRU: Yes Status: Orderable 5198566 cable-gantry - EKG PRO See Long Discription for Details Part #: 5198566 Part Type: GP CONSUMABLES Part Weight: 0.00 LBR Repairable: No Returnable: No Hazardous Material: N Description: cable-gantry - exg pro FRU: Yes Status: Orderable
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.