GE Healthcare · CTLightSpeedVCT200600013200501012200501020
LightSpeed 7.x (VCT, VCT Select, Pro32)
Symptom
Retro reconstructions fail. Retro reconstructions fail WITH Error:200600033 Attempting to produce retro series with 3032 images is not allowed The image number in Browser or in the image queue is already 2803. posted in error log, this is most likley to occur when customer is doing retro reconstructions of cardiac gated images
Error message
Error: 200600013 Problem converting scanner value to UIRx type. Field = matrix_size see long description for complete error Sat Jan 23 17:10:44 2010 Error: 200600013 Host: VCT9CN2 Process: retroRecon File: RetroSubSystemIf.c Line: 554 Problem converting scanner value to UIRx type. Field = matrix_size. Error: 200501012 Cannot translate to UIRxTypes enum Algorithm see long description for complete error Sat Jan 23 17:10:44 2010 Error: 200501012 Host: VCT9CN2 Process: retroRecon File: UIRxTypesToScanner.cxx Line: 1609 Function: Image Generation : OC Processing Unrocognized idb_value for algorithm (0). Cannot translate to UIRxTypes enum Algorithm Error: 200501020 Cannot translate to UIRxTypes enum MatrixSize see long description for complete error Sat Jan 23 17:10:44 2010 Error: 200501020 Host: VCT9CN2 Process: retroRecon File: UIRxTypesToScanner.cxx Line: 2306 Function: Image Generation : OC Processing Unrocognized value for matrix size (0). Cannot translate to UIRxTypes enum MatrixSize. Error: 200600013 Problem converting scanner value to UIRx type. Field = image_filter see long description for complete error Sat Jan 23 17:10:44 2010 Error: 200600013 Host: VCT9CN2 Process: retroRe
Applies to
- Models
- LightSpeed, VCT
- Product
- LightSpeed 7.x (VCT, VCT Select, Pro32) V40_H_V64_G_GTM V40_H_V64_G_GTL V40_H_V32_G_GTM V40_H_V32_G_GTL V40_H_H64_G_GTM V40_H_H64_G_GTL V40_H_HS64_G_G Product Name: LightSpeed 7.x (VCT, VCT Select, Pro32) Product photographs Method of remote or software identification - See attachment for a complete list of software commands and typical results. check_config swhwinfo “swhwinfo” will have the following new switches available with the VCT M4 and PF 1.5 M3 software release (software release deploying this “swhwinfo” capability is “06MW03.?”): · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) · -h or –help = Outputs complete details about all the available switches associated with swhwinfo · swhwinfo –c –m –o -da List of Supported Console Types GOC5 Will have a VDARC and VIG GOC6 Will have a VDIG List of softwares the product can run 09MW08.10 09MW08.11 08MW33.2 07MW18.4 06MW03.4 05MW31.6 FAQ's Table weight limit - Up to 500 lb. (227 kg) with ± .25 mm positional accuracy Tube type - D3194T D3193T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system. Done acording to template
- Software
- 08MW33.2 for GOC6 LightSpeed VCT (64 Slice Only) 11/17/2008 Inital M3 release. This software is now obsolete, this site should be upgraded to 11HW12.5 software released via FMI 25427 08MW33.2 for GOC6 LightSpeed VCT (64 Slice Only) 11/17/2008 Inital M3 release. LightSpeed 7.1 ( 08MW33.2 ) Software Release supports GOC6 consoles used on VCT 64, VCT XT & VCT Std. - LightSpeed 7.1 (08MW33.2)Software for GOC6 Collector 5318369 Rev 1 Includes OS and Application CD's - Operating System Linux 5.2.13 Software CD 5318646 Rev 1 - Application LightSpeed VCT GOC6 DVD 5317935 Rev 1 - Class C LightSpeed 7.1 5318761 Rev 1 - Class M LightSpeed 7.1 5317906 Rev 1 An On-site/Remote identification aid . (Example: check_config) Result from check_config or swhwinfo 08MW33.2 V40_PS_HD64_G_GTM 08MW33.2 V40_PS_HD64_G_GTL Please create an ITRAK report for any software related issues
- Area
- CT