Pular para o conteúdo principal
GE Healthcare · CTLightSpeed26000311626000314250001

LightSpeed 4.X - GRE

Symptom

Scanning aborts with collimator filter homing problem. Scanning aborts with collimator filter homing problem

Error message

Error: 260003116 Filter drive tracking detected no motion when motion was requested. See long description for sample error. Fri Sep 14 10:15:52 2007 Error: 260003116 Host: orp Process: orp subsys File: ccb drive timers.c Line: 504 Fri Sep 14 10:15:51 2007 Host : Collimator Ermes # : 260003116 Exception Class : Abort Severity : Primary File : ccb drive timers.c Line# : 504 Function : No System Function Reported Scan Type : Helical Scan: 8516/3/20 Filter drive tracking detected no motion when motion was requested. Verify operation of stepper motor and encoder feedback Start Position = 41999um 39697cnt Desired Position = 0um 0cnt Current Motor Position = 40415um 38200cnt Current Encoder Position= 41998um 39696cnt

Error: 260003142 The Filter failed to move to the requested position See long description for more details Sun Apr 8 06:41:17 2007 Error: 260003142 Host: HSC Process: CCB Firmware File: filter_move.c Line: 104 Function: XRAY GENERATION : Xray Collimation and Filtration Scan: 50001/2/0 Type: None/Unknown Exception Level: Pri/Soft Time: 06:41:17:580 Log Series: 46 The Filter failed to move to the requested position.

Applies to

Models
LightSpeed
Product
LightSpeed 4.X - GRE See Long Description for detailed information - H2_P_M16 Product Name: LightSpeed 4.X with GRE Product Photographs GE HEALTHCARE Method of remote or software identification - See attachment below for a complete list of software commands and typical results 1. check_config 2 . swhwinfo “swhwinfo” will have the following switches: · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) -h or –help = Outputs complete details about all the available switches associated with swhwinfo swhwinfo –c –m –o -da List of Supported Console types: GOC3 (GRE) GOC4 (GRE) List of software the product can run: 07MW11.10 SP2.0, SP3.0, SP3.1 FAQ's Table weight limit - 180 kg (400 lbs) normal operation - 205 kg (450 lbs) maximum allowed with decreased accuracy Tube type - D3186T D3186T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
Component
5331736 - Helios Filter Asselmbly FRU (replaces 2291958) Used on Helios 3 and 4 Collimators. See Long Description for more Details Part #: 5331736 Part Type: GP CONSUMABLES Part Weight: 0.00 LBR Repairable: No Returnable: No Hazardous Material: N Description: Helios Filter Asselmbly FRU FRU: Yes Status: OrderableComments: Per ECR 2082045, 212008898, 6/16/09. Part #: 2126674 Part Type: GP CONSUMABLES Part Weight: -144548.55 LBR Repairable: No Returnable: No Hazardous Material: N Description: FILTER ASSEMBLY, HELIOS COLLIMATOR FRU: NO Status: Non Orderable
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.

7-day free trial · no credit card required