Pular para o conteúdo principal
GE Healthcare · CTLightSpeedVCT260101046260101044260001039

LightSpeed 3.X (Ultra, Plus, QX/i) - GRE

Symptom

Flash Download fails for CCB after console upgrade

Error message

Error: 260101046 The CCB sub-system failed to indicate a reset occurred. See LD for more details Fri Sep 8 07:32:30 2006 Error: 260101046 Host: orp Process: orp_subsys File: rcib_node_init.c Line: 308 Fri Sep 8 07:32:28 2006 Host : On-Board Rotating Processor Ermes # : 260101046 Exception Class : Soft Severity : Pri/Soft File : rcib_node_init.c Line# : 308 Function : No System Function Reported Scan Type : None/Unknown Scan: 0/0/0 Reset error: The CCB sub-system failed to indicate a reset occurred. Reset the sub-system and try again. Verify visually that reset occurred.

Error: 260101044 Firmware error: Application file download failed Communications with the CCB sub-system is down. See LD for error example Fri Jun 16 10:39:20 2006 Error: 260101044 Host: orp Process: orp_subsys File: rcib_download_state.c Line: 101 Running Version Management Tool Fri Jun 16 10:39:19 2006 Host : On-Board Rotating Processor Ermes # : 260101044 Exception Class : Secondary Severity : Sec/Soft File : rcib_download_state.c Line# : 101 Function : No System Function Reported Scan Type : None/Unknown Scan: 0/0/0 Firmware error: Application file download failed. Communications with the CCB sub-system is down

Applies to

Models
LightSpeed, VCT
Product
LightSpeed 3.X (Ultra, Plus, QX/i) - GRE Always 4 or 8 slice MDAS. H2_P_M4 H2_P_M8 LightSpeed 3.X - GRE Method of visual identification Small rounded gantry similar in appearance to LS 2.X and 4.X. Always has an MDAS4 or MDAS8 Method of remote or software identification - See attachment below for a complete list of software commands and typical results. check_config “swhwinfo” will have the following new switches available with the VCT M4 and PF 1.5 M3 software release (software release deploying this “swhwinfo” capability is “06MW03.?”): · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) -h or –help = Outputs complete details about all the available switches associated with swhwinfo swhwinfo –c –m –o -da Always has an MDAS4 or MDAS8 List of Supported Console Types GOC3 Will have a DARC, SDDA and IG GOC4 Will have a DARC 2 and IG List of softwares the product can run 07MW11.10 SP3 06MW29.7 - obsolete 06MW03.5 - obsolete 05MW14.5 - obsolete 04MW44.9 - obsolete 04MW13.7 - obsolete FAQ's Table weight limit - Up to 400 lb. (180 kg) with ± .25 mm positional accuracy. 450Ib (205 kg) max weight Tube type - D3186T Current production details - See Technical Reference Manual found on the Common Document Library Tips and workarounds, where to find it - Common Document Library(CDL) . Search for the latest FMI software release. In the furnished materials will be the list of various manuals with part numbers for the various languages. Example: English versions 2211223-100 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
Component
2159578-3 collimator control board used on 1X/2X/3X/4X/5X See Long description for details Part #: 2159578-3 Part Type: GP CONSUMABLES Part Weight: 2.18 LBR Repairable: No Returnable: No Hazardous Material: N Description: COLLIMATOR CONTROL BOARD FRU: Yes Status: Orderable Comments: Not Available
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.