System is Logging 2277671 ICN sensor detects value out of range, but System is Running Fine.
Symptom
System is Logging 2277671 ICN sensor detects value out of range, but System is Running Fine See Long Description The system is logging the following error once every hour, for each of the system's four ICNs. Other than logging the error, there doesn't seem to be any other impact on the system. The system is running fine. Should we troubleshoot this error? SPR # MRIhc45772 Error: 2277671 Host: Signa-3 Process: diagCoord File: /export/home/signa/vre/diags/sen Line: 614 Exception Class: Notification Function: Software/Firmware/Config: N/A ICN sensor detects value out of range. ICN: [icn2 MAC=00:30:48:58:93:26 SERIAL=1495807] Sensor: 1.8V Higher Limit: 0 Current Value: 1.836->
Error message
2277671 ICN sensor detects value out of range See Long Description Error: 2277671 Host: Signa-3 Process: diagCoord File: /export/home/signa/vre/diags/sen Line: 614 Exception Class: Notification Function: Software/Firmware/Config: N/A ICN sensor detects value out of range. ICN: [icn2 MAC=00:30:48:58:93:26 SERIAL=1495807] Sensor: 1.8V Higher Limit: 0 Current Value: 1.836-> Extended Error: 2277671 ERROR: EM_DIAG_ICN_SENSOR_OUT_OF_RANGE ICN sensor detects value out of range. ICN: %s Sensor: %s %s Limit: %s Current Value: %s Extended Error: Check detected hardware of ICN Possible cause(s): Img Compute Node
Applies to
- Models
- Signa
- Product
- Signa HDxT This product is for 1.5T Signa HDxT systems with 15.0 software and HDi systems with 15.0 software. This product is for 1.5T Signa HDxT systems with 15.0 software and HDi systems with 15.0 software.
- Software
- 15.0 For Product Signa HDxT and HDi only. -- NOT to be used with HDe. -- For Product Signa HDxT and HDi only. -- NOT to be used with HDe. --
- Area
- MR
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare MR issues
- Running grafidy3, and find there are spikes on the waveforms in the manual prescan display, both windows.
- Fails to Scan with TORSO Coil.
- The Carriage Fails to Advance to Latch to the Table and to Retract When it is Raised, Undocked or Lowered.
- AE title has changed on destination host.
- CWA ID100315. Auto and Manual Prescan Fails.
- What is the Acoustic Noise Level in the Ovation Magnet.