GE Healthcare · CTHiSpeedVCT260006829148262600068035007926000660550000
Scanner Hardware Stopped Scan
Symptom
Scanner Hardware Stopped Scan. Scanner Hardware Stopped Scan
Error message
Error: 260006829 Axial Motor Logic is NOT recording the average current data from AB drive. Attempts to read the data failed. CAN communication failures. See long description for an example. Tue Aug 25 11:38:21 2009 Error: 260006829 Host: STC Process: Axial File: amc stats.c Line: 75 Function: AXIAL CONTROL : axial communications Scan: 14826/2/1 Type: Helical Exception Level: Sec/Soft Time: 11:38:21:925 Log Series: 745 Axial Motor Logic is NOT recording the average current data from AB drive. Attempts to read the data failed. CAN communication failures. Error: 260006803 Axial Motor Control (AMC) logic could NOT access the AXIAL drive via the CAN network. See long description for complete error Error: 260006803 Host: STC Process: Axial File: amc_exec.c Line: 3077 Function: AXIAL CONTROL : axial communications Scan: 50079/4/0 Type: None/Unknown Exception Level: Pri/Most Severe Time: 05:23:06:435 Log Series: 505 Axial Motor Control (AMC) logic could NOT access the AXIAL drive via the CAN network. Error: 260006605 Could not send axial drive message in the allotted time. Axial serial link is down. See the LD for the full error code Error: 260006605 Could not send axial drive message i
Applies to
- Models
- HiSpeed, VCT
- Product
- HiSpeed QX/i - GOC2 103L.5_HSQXIM4 103L.4_HSQXIM4 102L.1_HSQXIM3 HiSpeed QX/i - GOC2 Method of visual identification Method of remote or software identification - See attachment below for a complete list of software commands and typical results. check_config List of Supported Console Types GOC2 List of softwares the product can run 103L.5_HSQXIM4 103L.4_HSQXIM4 - obsolete 102L.1_HSQXIM3 - obsolete FAQ's Table weight limit - Up to 400 lb. (180 kg) with ± .25 mm positional accuracy. 450Ib (205 kg) max weight Tube type - D3186T Current production details - See Technical Reference Manual found on the Common Document Library Tips and workarounds, where to find it - Common Document Library(CDL) . Search for the latest FMI software release. In the furnished materials will be the list of various manuals with part numbers for the various languages. Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Component
- 5311936 Axial Encoder Assembly, Hub-Mounted Wheel. Used on H2, HP, VCT, and HD750. (Replaces 5182284-2 /5182284 / 2369747-2 / 2369747 / 2328307) See LD for details 5311936 Axial Encoder Assembly, Hub-Mounted Wheel. Used on H2, HP and VCT. (Replaces 5182284-2 /5182284 / 2369747-2 / 2369747 / 2328307) Part #: 5311936 Part Type: GP CONSUMABLES Part Weight: 0.00 LBR Repairable: No Returnable: No Hazardous Material: N Description: Shipping collector for Axial Encoder Assembly. FRU: Yes Status: Orderable Comments: Per ECR 2058601, 212008898, 10/8/08
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required