LightSpeed 4.X - GRE
Symptom
Scanner Hardware Stopped Scan. Scanner Hardware Stopped Scan
Error message
Error: 245061 Process: scanmgr SCNMGR_ACQUISITION_DONE event was not received See LD for complete error Wed Feb 28 17:50:15 2007 Error: 245061 Host: ct99 Process: scanmgr File: norm_and_gen_timeouts.cxx Line: 90 Function: System Control : Scan Control Scan Type: Helical Scan: 0/0/0 Scan Seq Id: 1342000 SCNMGR_ACQUISITION_DONE event was not received Error: 230000024 Timeout expired waiting for the DIP to receive a buffer of views. See LD for more details Error: 230000024 Timeout expired waiting for the DIP to receive a buffer of views. Wed Mar 22 03:38:05 2006 Error: 230000024 Host: darc Process: dataacq File: dip thread.cxx Line: 612 Function: Data Acquisition : Scan Data Acquisition Scan Type: Cine Scan: 50016/6/1 Scan Seq Id: 189000 Timeout expired waiting for the DIP to receive a buffer of views. Timeout value: 250 msecs Offsets collected: 404c598h bytes Minimum offsets: 1f544c4h bytes Active data collected: 8000000h bytes Active data expected: 242eb1c8h bytes Scan aborted. Do not Use - use one of the other Error: 290009009 Image failed due to many reasons See Long Description for complete error Tue Apr 19 12:44:49 2005 Error: 290009009 Host: darc Process: recon_control File:
Applies to
- Models
- LightSpeed
- Product
- LightSpeed 4.X - GRE See Long Description for detailed information - H2_P_M16 Product Name: LightSpeed 4.X with GRE Product Photographs GE HEALTHCARE Method of remote or software identification - See attachment below for a complete list of software commands and typical results 1. check_config 2 . swhwinfo “swhwinfo” will have the following switches: · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) -h or –help = Outputs complete details about all the available switches associated with swhwinfo swhwinfo –c –m –o -da List of Supported Console types: GOC3 (GRE) GOC4 (GRE) List of software the product can run: 07MW11.10 SP2.0, SP3.0, SP3.1 FAQ's Table weight limit - 180 kg (400 lbs) normal operation - 205 kg (450 lbs) maximum allowed with decreased accuracy Tube type - D3186T D3186T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required