GE Healthcare · CTLightSpeedVCT260107212

LightSpeed 5.X (80/100kW)

Symptom

Scanner Hardware Stopped Scan. Scanner Hardware Stopped Scan

Error message

Error: 260107212 Gantry Failed to change to Commanded Velocity of x.x secs/rev within x.000 seconds. Velocity is dependent on what was selected Wed Aug 25 19:08:26 2004 Error: 260107212 Host: tgp Process: tgp_subsys File: amc_mgr.c Line: 3557 Wed Aug 25 19:08:25 2004 Host : Table Gantry Processor Ermes # : 260107212 Exception Class : Abort Severity : Primary File : amc_mgr.c Line# : 3557 Function : AXIAL CONTROL : Axial Control Scan Type : Axial Scan: 598/1/1 Gantry Failed to change to Commanded Velocity of 2.0 secs/rev within 20.000 seconds. (AMC state:4 Cmd:21 CurVel:2147 (.001 sec/rev)) Retry Rx to verify probable Axial Drive or Gantry Balance or Encoder Hardware. Example with 1 second rotation selected: Wed Aug 25 19:09:42 2004 Error: 260107212 Host: tgp Process: tgp_subsys File: amc_mgr.c Line: 3557 Wed Aug 25 19:09:41 2004 Host : Table Gantry Processor Ermes # : 260107212 Exception Class : Abort Severity : Primary File : amc_mgr.c Line# : 3557 Function : AXIAL CONTROL : Axial Control Scan Type : Axial Scan: 598/1/1 Gantry Failed to change to Commanded Velocity of 1.0 secs/rev within 20.000 seconds. (AMC state:4 Cmd:21 CurVel:1480 (.001 sec/rev)) Retry Rx to verify probable Ax

Applies to

Models
LightSpeed, VCT
Product
LightSpeed 5.X (80/100kW) LightSpeed 5.X (80/100kW) ~ Use with both MDAS and GDAS ~ GRE Console HP_H_G16 HP_H_M16 HP_O_M16 LightSpeed 5.X (100kW) GDAS16 with GRE Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
Component
5311936 Axial Encoder Assembly, Hub-Mounted Wheel. Used on H2, HP, VCT, and HD750. (Replaces 5182284-2 /5182284 / 2369747-2 / 2369747 / 2328307) See LD for details 5311936 Axial Encoder Assembly, Hub-Mounted Wheel. Used on H2, HP and VCT. (Replaces 5182284-2 /5182284 / 2369747-2 / 2369747 / 2328307) Part #: 5311936 Part Type: GP CONSUMABLES Part Weight: 0.00 LBR Repairable: No Returnable: No Hazardous Material: N Description: Shipping collector for Axial Encoder Assembly. FRU: Yes Status: Orderable Comments: Per ECR 2058601, 212008898, 10/8/08
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.

7-day free trial · no credit card required

Related GE Healthcare CT issues