CWA Computer will not boot up to applications level, with the message on the screen that says Please do not interact wit…
CWA Computer will not boot up to applications level, with the message on the screen that says Please do not interact with the system until this message disappears.
Symptom
Computer will not boot up to applications level, with the message on the screen that says Please do not interact with the system until this message disappears. Computer will not boot up to applications level, with the message on the screen that says -- > Please do not interact with the system until this message disappears. If the system does not come up in 15 minutes, please call your service representative.
Error message
2252112 Board SCP is in invalid power up state 2 See Long Description Verify ENV parameters and retry power up. Extended Error: The board may be in one of the following states: 0 - No response, 1 - OS Loaded, 2 - PPC Bug, 3 - PPC Diag, 4 - OS not loaded If the error message states that the board is in state 4, then the OS load was stopped. This may happen if characters are detected on the serial cable. In order to eliminate this problem, disconnect the serial cable from AGP/COM1 Connector or SCP/Console Connector and reboot the board. If the error message states that the board is in state 2 or 3, then run the Motorola Board Level Diagnostics to verify the board is OK. If the BLD passes but this message appears during TPS reset then it is highly probable that the boards are not being reset by STIF connection. You can verify if the boards are not being reset by STIF connection during TPS reset either by looking at the LEDs on front of the boards or by opening MGD Terminal window. 2223852 The AGP board reported a communication manager (CM) initialization error. Please check the error log for a more detailed error message from the board.-> Extended Error : MCP820 boards can be identif
Applies to
- Models
- Signa
- Product
- Signa HDxT This product is for 1.5T Signa HDxT systems with 15.0 software and HDi systems with 15.0 software. This product is for 1.5T Signa HDxT systems with 15.0 software and HDi systems with 15.0 software.
- Software
- 15.0 For Product Signa HDxT and HDi only. -- NOT to be used with HDe. -- For Product Signa HDxT and HDi only. -- NOT to be used with HDe. --
- Area
- MR
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare MR issues
- Running grafidy3, and find there are spikes on the waveforms in the manual prescan display, both windows.
- Fails to Scan with TORSO Coil.
- The Carriage Fails to Advance to Latch to the Table and to Retract When it is Raised, Undocked or Lowered.
- AE title has changed on destination host.
- CWA ID100315. Auto and Manual Prescan Fails.
- What is the Acoustic Noise Level in the Ovation Magnet.