Pular para o conteúdo principal
GE Healthcare · CTDiscovery23001500524521511000230015036245201230015016

Collimator Aperture Test Fails

Symptom

Collimator Aperture Test Fails

Error message

Error: 230015005 Unable to retrieve the requested cal module from the Cal Database Sun Jun 19 21:05:13 2005 Error: 230015005 Host: wodct03403 Process: scanmgr File: cal_db_api.c Line: 451 Function: CAL Processing : SBC Processing Unable to retrieve the requested cal module from the Cal Database

Error: 245215 Scan setup failed on Step:0 (Getting Tracking Module) Status:-1 See Long Description for detail Error: 245215 Scan setup failed on Step:0 (Getting Tracking Module) Status: -1 Wed Feb 20 16:26:01 2008 Error: 245215 Host: bay44 Process: scanmgr File: scanmgr_lib.cxx Line: 1156 Function: System Control : Scan Control Scan Type: Scout Scan: 0/0/0 Scan Seq Id: 11000 Scan setup failed on Step:0 (Getting Tracking Module). Status:-1

Error: 230015036 /usr/g/cal_db/tracking/coll_cal/2x0625/small_spot/ collimator_cal does not exist See Long Description for Details Wed Feb 20 16:26:57 2008 Error: 230015036 Host: bay44 Process: scanUtilsRx File: cal_db_utils.c Line: 1235 /usr/g/cal_db/tracking/coll_cal/2x0625/small_spot/collimator_cal does not exist

Error: 245201 The current scan has been aborted due to an invalid tracking calibration See Long Description for details Wed Feb 20 16:26:01 

Applies to

Models
Discovery
Product
Discovery CT750 HD V40_PS_HD64_G_GTL V40_PS_HD64_G_GTM Discovery HD CT750 Method of visual identification HD gantry: Gray top and Gray Side covers with HD Markings Console Type: GOC6 has black SCIM and tower face Method of remote or software identification - See attachment below for a complete list of software commands and typical results. check_config swhwinfo “swhwinfo” will have the following new switches available · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) -h or –help = Outputs complete details about all the available switches associated with swhwinfo swhwinfo –c –m –o -da List of softwares the product can run (Consult attached FCT Software Cross Reference): 08MW39.4 - M3 (see attachement for M3 available options) 09MW29.14 - M4 (HD Options = M3 plus Gemstone Spectral Imaging, Gemstone Spectral Review and volume Helical Shuttle ) Example: Of difference with options software [insite@ct01 ~]$ swokinstall -p Product Software Option Keys: Gemstone Spectral Imaging Permanent HelicalShuttle Permanent Xtream Recon Permanent FAQ's Table weight limit: 500 lbs Tube Type - D3702T Green D3701T Current production - M4 Refer to product data sheets or Technical reference Manual, English 5317222-1EN Revision : 2 or later Refer to Application Tips and Work-Arounds Direction 5311815-1EN Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.

7-day free trial · no credit card required

Related GE Healthcare CT issues