GE Healthcare · CTLightSpeedVCT182865225672818795
LightSpeed 2.X (Plus, QX/i) - GRE
Symptom
Gantry Control Panel not working. Long Description for Feedback Only. Gantry Control Panel not working.
Error message
Error: 182865 STUCK BUTTON detected on Gantry Controls See the LD for the full error code Tue Sep 13 18:09:37 2005 Error: 182865 Host: ETC Process: Gantry Display File: gd tnc erlog.c Line: 782 Function: No System Function Reported Scan: 9160/5/0 Type: None/Unknown Exception Level: Pri/Soft Time: 18:09:37:415 Log Series: 928 STUCK BUTTON detected on Gantry Controls . Node Id: 4 , Button: ALIGNMENT LIGHT BUTTON. Board Number: 2256728 Serial Number: 18795.
Applies to
- Models
- LightSpeed, VCT
- Product
- LightSpeed 2.X (Plus, QX/i) - GRE always an SDAS 4 slice H2_P_S4 (SDAS4 and H2 gantry) Lightspeed 2.X - GRE Method of visual identification Small rounded gantry similar in appearance to LS 3.X and 4.X. Always has an SDAS 4 slice Method of remote or software identification - See attachment below for a complete list of software commands and typical results. check_config “swhwinfo” will have the following new switches available with the VCT M4 and PF 1.5 M3 software release (software release deploying this “swhwinfo” capability is “06MW03.?”): · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) -h or –help = Outputs complete details about all the available switches associated with swhwinfo swhwinfo –c –m –o -da List of Supported Console Types GOC3 Will have a DARC, SDDA and IG GOC4 Will have a DARC 2 and IG List of softwares the product can run 07MW11.10 SP3 06MW29.7 - obsolete 06MW03.5 - obsolete 05MW14.5 - obsolete 04MW44.9 - obsolete 04MW13.7 - obsolete FAQ's Table weight limit - Up to 400 lb. (180 kg) with ± .25 mm positional accuracy. 450Ib (205 kg) max weight Tube type - D3186T Current production details - See Technical Reference Manual found on the Common Document Library Tips and workarounds, where to find it - Common Document Library(CDL) . Search for the latest FMI software release. In the furnished materials will be the list of various manuals with part numbers for the various languages. Example: English versions 2211223-100 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Component
- 5139591 control assembly right side gantry ( replaces part# 2256728 and 2330703 ) ) – used on LightSpeed 2.x, 3.x, 4.x, 5.x, 7.x (HD uses a different control panel) See Long Description. 5139591 control assembly right side gantry ( replaces part# 2256728 and 2330703 ) ) – used on H2 gantry,s (LightSpeed 2.x, 3.x, 4.x, 5.x, 7.x ) Part #: 5139591 Part Type: GP CONSUMABLES Part Weight: 2.20 LBR Repairable: No Returnable: No Hazardous Material: N Description: H POWER OPERATOR CONTROLS RIGHT SIDE FRU: Yes Status: Orderable OLD part info 2256728 control assembly right gantry Part #: 2256728 Part Type: GP CONSUMABLES Part Weight: 0.00 LBR Repairable: No Returnable: No Hazardous Material: N Description: CONTROL ASM RIGHT H2 GANTRY FRU: Yes Status: Orderable Comments: If no stock is available, order 5139591 per ECR 2025944; 6/20/2006 MS11892 FLS - PLEASE CONVERT SPH ORDER TO OVERNIGHT SHIPMENT IF PART AVAILABLE IN MEMPHIS AND IF FEDEX SERVICE (INCLUDING 8:00 AM SERVICE) MEETS FE NEED TIME CRITERIA Part #: 2330703 Part Type: GP CONSUMABLES Part Weight: 2.18 LBR Repairable: No Returnable: No Hazardous Material: N Description: H POWER OPERATOR CONTROLS RIGHT SIDE FRU: Yes Status: Orderable Parts Offered as: Current: 2330703 Harvested: Not Available Exchange: Not Available Comments: If no stock is available, order 5139591 per ECR 2025944; 6/20/2006 MS11892. 212012201 02/09/2007 19:34 GMT
- Area
- CT
Full cause & step-by-step resolution