GE Healthcare · CTLightSpeedVCT230000067117000
LightSpeed 7.x (VCT, VCT Select, Pro32)
Symptom
Scanner Hardware Stopped Scan with slip ring communication errors Scanner Hardware Stopped Scan with slip ring communication errors.
Error message
Error: 230000067 RX1 or RX2 Bad View Error See LD for more details Error: 230000067 RX2 Bad View Error Wed Mar 22 01:38:18 2006 Error: 230000067 Host: darc Process: dataacq File: vdip.cxx Line: 872 Function: Data Acquisition : Scan Data Acquisition Scan Type: Axial Scan: 7024/2/2 Scan Seq Id: 117000 Unexpected event occurred during scan data transfer. Event bit: 13 Count: 1 Description: RX2 Bad View Error Scan aborted.
Applies to
- Models
- LightSpeed, VCT
- Product
- LightSpeed 7.x (VCT, VCT Select, Pro32) V40_H_V64_G_GTM V40_H_V64_G_GTL V40_H_V32_G_GTM V40_H_V32_G_GTL V40_H_H64_G_GTM V40_H_H64_G_GTL V40_H_HS64_G_G Product Name: LightSpeed 7.x (VCT, VCT Select, Pro32) Product photographs Method of remote or software identification - See attachment for a complete list of software commands and typical results. check_config swhwinfo “swhwinfo” will have the following new switches available with the VCT M4 and PF 1.5 M3 software release (software release deploying this “swhwinfo” capability is “06MW03.?”): · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) · -h or –help = Outputs complete details about all the available switches associated with swhwinfo · swhwinfo –c –m –o -da List of Supported Console Types GOC5 Will have a VDARC and VIG GOC6 Will have a VDIG List of softwares the product can run 09MW08.10 09MW08.11 08MW33.2 07MW18.4 06MW03.4 05MW31.6 FAQ's Table weight limit - Up to 500 lb. (227 kg) with ± .25 mm positional accuracy Tube type - D3194T D3193T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system. Done acording to template
- Component
- 2376399 2.5 GB 2 CHANNEL HSDCD SLIPRING ASM See Long description for details Part #: 2376399 Part Type: GP CONSUMABLE - RETURNABLE Part Weight: 2.18 LBR Repairable: No Returnable: Yes Hazardous Material: N Description: 2.5 GB 2 CHANNEL HSDCD SLIPRING ASM FRU: Yes Status: Orderable
- Area
- CT