GE Healthcare · CTLightSpeedVCT244635244636244644244643

LightSpeed 7.x (VCT, VCT Select, Pro32)

Symptom

Tube identification hardware not detected reported on boot up

Error message

Error: 244635 System hardware auto-detected incorrect tube type than the SW is currently configured for. Scanning is disabled. See long description Sun Oct 11 18:25:20 2009 Error: 244635 Host: sjct Process: fwmgr File: fwmgr_fw_if.cxx Line: 447 Function: No system function reported Scan Type: Not scanning Scan: 0/0/0 Scan Seq Id: 0 System hardware auto-detected incorrect tube type than the SW is currently configured for. Scanning is disabled.

Error: 244636 Please verify the tube type, run reconfig or reload software and perform a Flash Download to correct this problem. See long description Sun Oct 11 18:25:20 2009 Error: 244636 Host: sjct Process: fwmgr File: fwmgr_fw_if.cxx Line: 449 Function: No system function reported Scan Type: Not scanning Scan: 0/0/0 Scan Seq Id: 0 Please verify the tube type, run reconfig or reload software and perform a Flash Download to correct this problem. Status from the generator: -1

Error: 244644 Tube identity advisory: Advisory messages will be posted to the operator about an unrecognized tube during system startup, during tube warm-up, during Fast Calibration, and in the dose report. See LD for more details Sat Jun 17 10:21:57 2006 Error: 244644 

Applies to

Models
LightSpeed, VCT
Product
LightSpeed 7.x (VCT, VCT Select, Pro32) V40_H_V64_G_GTM V40_H_V64_G_GTL V40_H_V32_G_GTM V40_H_V32_G_GTL V40_H_H64_G_GTM V40_H_H64_G_GTL V40_H_HS64_G_G Product Name: LightSpeed 7.x (VCT, VCT Select, Pro32) Product photographs Method of remote or software identification - See attachment for a complete list of software commands and typical results. check_config swhwinfo “swhwinfo” will have the following new switches available with the VCT M4 and PF 1.5 M3 software release (software release deploying this “swhwinfo” capability is “06MW03.?”): · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) · -h or –help = Outputs complete details about all the available switches associated with swhwinfo · swhwinfo –c –m –o -da List of Supported Console Types GOC5 Will have a VDARC and VIG GOC6 Will have a VDIG List of softwares the product can run 09MW08.10 09MW08.11 08MW33.2 07MW18.4 06MW03.4 05MW31.6 FAQ's Table weight limit - Up to 500 lb. (227 kg) with ± .25 mm positional accuracy Tube type - D3194T D3193T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system. Done acording to template
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.