No exposure to a TRAD receptor (Table or Wallstand) with an inhibit on the OTS UIF
Symptom
No exposure to a TRAD receptor (Table or Wallstand) with an inhibit on the OTS UIF See Long Description 1) Customer is unable to take an exposure to a TRAD receptor (either Table or Wallstand) and the system shows an inhibit on the OTS UIF and the Console stating: "Portable detector not docked. Insert detector inside table (or wallstand)". 2) In some cases, the customer then switches to override mode and the inhibit is no longer displayed. The customer attempts an exposure and it fails. The detector is in the detector tray and the detector appears to be inserted.
Error message
1000011 "Failed to execute StartPrepare script" 200013 "Time out while waiting for an event or an actor to respond"
Applies to
- Models
- Discovery, Optima
- Product
- Discovery XR650 Optima XR640
- Software
- XR650 and XR640 M3 See Long Description for Config.txt file. atlasidc-2.1-6 atlas_linux_release-7.9-0 calypso-8.70-2 can_pci266_2615_smp-7.9-ctt627 CSD-2.4A-1 detector-1.1-6 dmcots-1.1-15 dm_Platform_release-1.1-15 ea3-3.2-5 enggui-15.4-3 FlightRecorder-15.13-ATL.7.9 GlobalOneChinaFW_V4-1-2 IIPClassA-3.3.12-3 IIPClassM-3.3.12-3 IPCots-4.2-1 iui_globalone_release-5.1-23 j2re-1_4_2_13-linux-i586 j2sdk-1_4_2_13-linux-i586 jedi_lightning_magic-6.33BF6-1 machineDB-2-5 magic-aux_tools-1-1 magic-config_prod_GlobalOne-1-1 magic-cots-4-58 mcf_release-1.7-0 pnf-2.5-3 pos_download_mke-1-22 psys_can_pci266_2615_smp-7.9-ctt627 rcim2_smp_linux-7.9-0 RCOC-1.2.8-0 RTIP_G1_Magic_Release-FW17-RC3 saber_release-2.3.64C-1 SysConfig_Linux-103B-ATL.7.8.6 tao_linux_release-7.9-0 CD-R Label Data: 1) Business Name: Global Diagnostic X-Ray 2) CD-R Part Number: 5316167-3 3) Revision: 4 4) Software Title: Application Software 5) Disc Number: 1 of 1 6) Product Name: Discovery XR650/Optima XR640 7) Legally Required Messages ONLY: 8) Duplication Date: 9) Copyright Date: 2009
- Area
- X-ray R&F
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare X-ray R&F issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare X-ray R&F issues
- Collimator light does not work from the RCIM2 even though the button is present
- Discovery XR650 or Optima XR640
- No procedure to copy IP looks from a Definium 8000 system to a Discovery XR650 or Optima 640 system
- When the ./xrdinstall.om script is run to install the Operator Manual and a specific language is selected (English, for example), nothing happens.
- Next button in the lower right corner of the 2nd page of the Edit View window is grayed out.
- Grid (any focal length) insertion is not recognized by the wallstand.