GE Healthcare · X-ray R&FOptimaDiscoveryDefinium
No procedure to copy IP looks from a Definium 8000 system to a Discovery XR650 or Optima 640 system
Symptom
No procedure to copy IP looks from a Definium 8000 system to a Discovery XR650 or Optima 640 system See Long Description The customer has customized the IP Looks on their Definium 8000 system and would like to use the same IP Looks on their Discovery XR650 or Optima XR640 system. The FE cannot find a procedure in the service manual describing how to take IP Looks from a Definium 8000 system and apply them to a Discovery XR650 or Optima XR640 system.
Applies to
- Models
- Optima, Discovery, Definium
- Product
- Optima XR640 Discovery XR650
- Software
- XR650 and XR640 M3 See Long Description for Config.txt file. atlasidc-2.1-6 atlas_linux_release-7.9-0 calypso-8.70-2 can_pci266_2615_smp-7.9-ctt627 CSD-2.4A-1 detector-1.1-6 dmcots-1.1-15 dm_Platform_release-1.1-15 ea3-3.2-5 enggui-15.4-3 FlightRecorder-15.13-ATL.7.9 GlobalOneChinaFW_V4-1-2 IIPClassA-3.3.12-3 IIPClassM-3.3.12-3 IPCots-4.2-1 iui_globalone_release-5.1-23 j2re-1_4_2_13-linux-i586 j2sdk-1_4_2_13-linux-i586 jedi_lightning_magic-6.33BF6-1 machineDB-2-5 magic-aux_tools-1-1 magic-config_prod_GlobalOne-1-1 magic-cots-4-58 mcf_release-1.7-0 pnf-2.5-3 pos_download_mke-1-22 psys_can_pci266_2615_smp-7.9-ctt627 rcim2_smp_linux-7.9-0 RCOC-1.2.8-0 RTIP_G1_Magic_Release-FW17-RC3 saber_release-2.3.64C-1 SysConfig_Linux-103B-ATL.7.8.6 tao_linux_release-7.9-0 CD-R Label Data: 1) Business Name: Global Diagnostic X-Ray 2) CD-R Part Number: 5316167-3 3) Revision: 4 4) Software Title: Application Software 5) Disc Number: 1 of 1 6) Product Name: Discovery XR650/Optima XR640 7) Legally Required Messages ONLY: 8) Duplication Date: 9) Copyright Date: 2009
- Area
- X-ray R&F
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare X-ray R&F issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare X-ray R&F issues
- AEC Backup Time message
- Definium 8000 Auto positioning does not work after a reset/reboot due to wall stand receptor at a hard limit during rebooting or repowering.
- Definium 8000 One or both monitors display the following message on every boot
- Definium 8000 Wallstand or Table Only Configurations running VolumeRAD M3 Software.
- Definium 8000 OTS Collimator has no power due to a tripped breaker (CB8) ont he Tube Suspension Logic (TSL) Board.
- Definium 8000 The Siemens Collimator has not power due to a tripped breaker (CB9) on the Tube Suspension Logic (TSL) Board.