Symptom
Operator started scan from the protocol but the start scan, Pause scan & Move to scan lights do not come on
Error message
Error: 260107249 The Loop Contactor status Changed to the OPEN state. See long description for full sample error message. Mon Oct 27 10:21:29 2008 Error: 260107249 Host: tgp Process: tgp subsys File: amc isr.c Line: 685 Mon Oct 27 10:21:28 2008 Host : Table Gantry Processor Ermes # : 260107249 Exception Class : Abort Severity : Primary File : amc isr.c Line# : 685 Function : AXIAL CONTROL : Axial Control Scan Type : Axial Scan: 30272/2/5 Gantry (Axial) LOOP CONTACTOR Change of State Interrupt. The Loop Contactor status Changed to the OPEN state. Axial Decel of Gantry Enabled. (AMC State:8 Cmd:21 CurVel:2000 (.001 sec/rev)). Error: 260118236 - (70-0501) DC bus out of range Wed Nov 26 12:56:16 2003 Error: 260118236 Host: orp Process: orp_subsys File: gen_exec.c Line: 1923 Wed Nov 26 12:56:14 2003 Host : Jedi Ermes # : 260118236 Exception Class : Abort Severity : Primary File : gen_exec.c Line# : 1923 Function : No System Function Reported Scan Type : Static Scan: 54034/1/4 (70-0501)DC bus out of range. Z6,Z7= 0h,0h Error: 260112011 Received Table Rx but the Table was NOT READY Error : 260112011 Received Table Rx but the Table was NOT READY Thu Sep 1 08:49:43 2005 Error: 260112011 H
Applies to
- Models
- LightSpeed, VCT
- Product
- LightSpeed 7.x (VCT, VCT Select, Pro32) V40_H_V64_G_GTM V40_H_V64_G_GTL V40_H_V32_G_GTM V40_H_V32_G_GTL V40_H_H64_G_GTM V40_H_H64_G_GTL V40_H_HS64_G_G Product Name: LightSpeed 7.x (VCT, VCT Select, Pro32) Product photographs Method of remote or software identification - See attachment for a complete list of software commands and typical results. check_config swhwinfo “swhwinfo” will have the following new switches available with the VCT M4 and PF 1.5 M3 software release (software release deploying this “swhwinfo” capability is “06MW03.?”): · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) · -h or –help = Outputs complete details about all the available switches associated with swhwinfo · swhwinfo –c –m –o -da List of Supported Console Types GOC5 Will have a VDARC and VIG GOC6 Will have a VDIG List of softwares the product can run 09MW08.10 09MW08.11 08MW33.2 07MW18.4 06MW03.4 05MW31.6 FAQ's Table weight limit - Up to 500 lb. (227 kg) with ± .25 mm positional accuracy Tube type - D3194T D3193T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system. Done acording to template
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required