GE Healthcare · CTLightSpeedVCT260133167188125017926010102350444260007402
LightSpeed 7.x (VCT, VCT Select, Pro32)
Symptom
Scanner Hardware Stopped Scan. Scanner Hardware Stopped Scan
Error message
Error: 260133167 - (CAM A/B or Filter A/B) drive monitoring detected no motion when motion. See Long Description for complete Cam A or B errors Sat Nov 11 17:17:25 2006 Error: 260133167 Host: orp Process: orp_subsys File: ccb_drive_timers.cxx Line: 543 Sat Nov 11 17:17:24 2006 Host : Collimator Ermes # : 260133167 Exception Class : Abort Severity : Secondary File : ccb_drive_timers.cxx Line# : 543 Function : No System Function Reported Scan Type : None/Unknown Scan: 18812/1/0 CAM B drive monitoring detected no motion when motion was requested. Verify operation of stepper motor and encoder feedback Start Position = 5881um 0cnt Desired Position = 1870um 1100cnt Current Motor Position = 3191um 751cnt Current Encoder Position= 5881um 0cnt Sun Mar 18 05:49:17 2007 Error: 260133167 Host: orp Process: orp_subsys File: ccb_drive_timers.cxx Line: 543 Sun Mar 18 05:49:15 2007 Host : Collimator Ermes # : 260133167 Exception Class : Abort Severity : Secondary File : ccb_drive_timers.cxx Line# : 543 Function : No System Function Reported Scan Type : Axial Scan: 50179/7/1 Filter A drive monitoring detected no motion when motion was requested. Verify operation of stepper motor and encoder feedbac
Applies to
- Models
- LightSpeed, VCT
- Product
- LightSpeed 7.x (VCT, VCT Select, Pro32) V40_H_V64_G_GTM V40_H_V64_G_GTL V40_H_V32_G_GTM V40_H_V32_G_GTL V40_H_H64_G_GTM V40_H_H64_G_GTL V40_H_HS64_G_G Product Name: LightSpeed 7.x (VCT, VCT Select, Pro32) Product photographs Method of remote or software identification - See attachment for a complete list of software commands and typical results. check_config swhwinfo “swhwinfo” will have the following new switches available with the VCT M4 and PF 1.5 M3 software release (software release deploying this “swhwinfo” capability is “06MW03.?”): · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) · -h or –help = Outputs complete details about all the available switches associated with swhwinfo · swhwinfo –c –m –o -da List of Supported Console Types GOC5 Will have a VDARC and VIG GOC6 Will have a VDIG List of softwares the product can run 09MW08.10 09MW08.11 08MW33.2 07MW18.4 06MW03.4 05MW31.6 FAQ's Table weight limit - Up to 500 lb. (227 kg) with ± .25 mm positional accuracy Tube type - D3194T D3193T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system. Done acording to template
- Component
- 5129998-2 ccb chassis assembly VCT-GAN-COLL This is actually the Collimator Control Board and the metal bracket only - it is NOT the complete collimator assembly. See LD for details 5129998-2 ccb chassis assembly VCT-GAN-COLL This is actually the Collimator Control Board and the metal bracket only - it is NOT the complete collimator assembly Part #: 5129998-2 Part Type: GP CONSUMABLE - RETURNABLE Part Weight: 0.00 LBR Repairable: No Returnable: Yes Hazardous Material: N Description: CCB Chassis Asm, VCT Failsafe VCT-GAN-COLL FRU: Yes Status: Orderable Comments: Added by ECR 2019627, Part of Failsafe Collimator for VCT, ms13452 051015 This part is direct replacement for 5129998, and 5123185. ms13452
- Area
- CT