GE Healthcare · MRSigna223331222333112224666

Intermittently Unable to Scan with CERD NETWORK ERROR due to UCERD Exciter II.

Symptom

Intermittently Unable to Scan with CERD NETWORK ERROR See Long Description Signa LX system, running 9.1 software, is intermittently unable to scan due to the CERD NETWORK ERRORS that are being logged, shown below. The frequency of occurrence is once every two to three weeks. When this happens, the customer recovers by shutting down and powering off the system, and then rebooting the system. Tue Jan 20 09:11:35 2009 2233312 2 SMMC_MR_HCD NSPTPS: 1383 CERD NETWORK ERROR The CAP has responded to a network packet transaction with the TPS but the response is invalid. The network software on the CAP is probably not running. Reset and/or power-cycle the TPS chassis. Tue Jan 20 09:11:36 2009 2233311 2 SMMC_MR_HCD NSPTPS: 1321 CERD NETWORK ERROR The TPS has placed a packet in DPR for the CAP to take, but the CAP has completely ignored it. The CERD DPR may be broke or (most likely) the network software is not running on the CAP. Reset and/or power-cyclethe TPS chassis. Tue Jan 20 09:11:36 2009 2224666 1 SMMC_MR_HCD psc PscMainControl.cc 1322 Auto Prescan failed, CERD NETWORK ERROR The TPS has placed a packet in DPR for the CAP to take, but the CAP has completely ignored it. The CERD DPR may be broke or (most likely) the network software is not running on the CAP. Reset and/or power-cycle the TPS chassis.

Error message

2233312 CERD Network Error. The CAP has Responded to a Network Packet Transaction with the TPS But the Response is Invalid 2233312 "CERD NETWORK ERROR The CAP has Responded to a Network Packet Transaction with the TPS But the Response is Invalid. The network software on the CAP is probably not running. Reset and/or power-cycle the TPS chassis."

2233311 CERD Network Error. The TPS has Placed a Packet in DPR for the CAP to Take, but the CAP has Completely Ignored it 2233311 "CERD NETWORK ERROR The TPS has placed a packet in DPR for the CAP to take, but the CAP has completely ignored it. The CERD DPR may be broke or (most likely) the network software is not running on the CAP. Reset and/or power-cycle the TPS chassis."

2224666 Auto Prescan failed, CERD NETWORK ERROR Tue Jan 20 09:11:36 2009 2224666 SMMC_MR_HCD pscPscMainControl.cc 1322Auto Prescan failed, CERD NETWORK ERRORThe TPS has placed a packet in DPR for the CAP to take, but the CAPhas completely ignored it. The CERD DPR may be broke or (most likely)the network software is not running on the CAP. Reset and/or power-cyclethe TPS chassis.

Applies to

Models
Signa
Product
Signa LX Signa LX Product can be used with 8.x and 9.x systems.
Software
9.1 For Signa LX product only
Component
2221399-6 UNIVERSAL CERD EXCITER II 2221399-6 UNIVERSAL CERD EXCITER II
Area
MR

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.