When protocols from pre HDxT software are upgraded onto HDxT software and when such protocols are scanned 'GRx Localizer…
When protocols from pre HDxT software are upgraded onto HDxT software and when such protocols are scanned 'GRx Localizer Screen Save' Images are created by default.
Symptom
When protocols are upgraded onto HDxT software and when such protocols are scanned 'GRx Localizer Screen Save' Images are created by default and saved in a different series in browser. See Long Description The customer's old pre-HDxT protocols were loaded onto the system. Every series of each protocol has the [save localizer] button enabled. Customer does not want the use of this feature. It is very annoying to them to have these series show up in the browser. I tried to go into the protocol library to turn off this feature, but it will not permit me to do this. iTrak # 13227507, SPR # MRIhc44053. Engineering investigation: Issue is reproducible in house. When protocols from pre HDxT software are upgraded onto HDxT software and when such protocols are scanned 'GRx Localizer Screen Save' Images are created by default and saved in a different series in browser. 'GRx Localizer Screen Save' information is captured in protocol under parameter 'GRXLOCSAVE' (0=>OFF, 1=>ON). If 'GRx Localizer Screen save' information is not captured explicitly in protocol, and when such protocols are scanned, by default 'GRx Screen Save Localizer' Images are generated and stored in browser.
Applies to
- Models
- Signa
- Product
- Signa HDxT This product is for 1.5T Signa HDxT systems with 15.0 software and HDi systems with 15.0 software. This product is for 1.5T Signa HDxT systems with 15.0 software and HDi systems with 15.0 software.
- Software
- 15.0 For Product Signa HDxT and HDi only. -- NOT to be used with HDe. -- For Product Signa HDxT and HDi only. -- NOT to be used with HDe. --
- Area
- MR
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare MR issues
- Running grafidy3, and find there are spikes on the waveforms in the manual prescan display, both windows.
- Fails to Scan with TORSO Coil.
- The Carriage Fails to Advance to Latch to the Table and to Retract When it is Raised, Undocked or Lowered.
- AE title has changed on destination host.
- CWA ID100315. Auto and Manual Prescan Fails.
- What is the Acoustic Noise Level in the Ovation Magnet.