GE Healthcare · CTLightSpeed18241850515
Lightspeed 1.X - Octane
Symptom
Scanner Hardware Stopped Scan. Scanner Hardware Stopped Scan
Error message
Error: 182418 Elevation Pushbutton select timeout detected by hardware. See LD for full Error Error: 182418 Elevation Pushbutton select timeout detected by hardware. Fri Dec 16 09:17:56 2005 Error: 182418 Host: ETC Process: Elevation File: emcControl.c 1.23 11/13/92 Line: 225 Function: PATIENT ANATOMY POSITIONING : Elevation - Tilt Scan: 50515/11/0 Type: None/Unknown Exception Level: Pri/Soft Time: 09:17:56:955 Log Series: 963 HW/SW error: Elevation Pushbutton select timeout detected by hardware. Current Position 1189 (.1 mm). Elev Direction: 1 (0 = Up 1 = Down).
Applies to
- Models
- LightSpeed
- Product
- Lightspeed 1.X - Octane 10.5_2.8.2I_H1.3M4 10.4.1_2.8.2I_H1.3M4 - obsolete Lightspeed 1.X - Octane Method of visual identification Method of remote or software identification - See attachment below for a complete list of software commands and typical results. check_config showprods|grep Apps note: if check_config does not work then the software is not up to date with all FMI's. Check FMI history and verify that all patches have been loaded since last software reload. Ref FMI 25269 List of Supported Console Types Octane with Pegasus Recon hardware. may have an 02 SBC - Run df -k to see if the sbc is partitioned. List of softwares the product can run 10.5_2.8.2I_H1.3M4 10.4.1_2.8.2I_H1.3M4 - obsolete FAQ's Table weight limit - Up to 400 lb. (180 kg) with ± .25 mm positional accuracy. 450Ib (205 kg) max weight Tube type - D3176T Current production details - See Technical Reference Manual found on the Common Document Library Tips and workarounds, where to find it - Common Document Library(CDL) . Search for the latest FMI software release. In the furnished materials will be the list of various manuals with part numbers for the various languages. Example: English versions 2211223-100 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Component
- 2225306-2 GANTRY CONTROL PANEL - LEFT SIDE - used on LS 1.X See Long Description Part #: 2225306-2 Part Type: GP CONSUMABLES Part Weight: 1.81 LBR Repairable: No Returnable: No Hazardous Material: N Description: GANTRY CONTROL PANEL - LEFT SIDE FRU: Yes Status: Orderable
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required