GE Healthcare · CTLightSpeedVCT2601120112601151851272744134927175000
LightSpeed 3.X (Ultra, Plus, QX/i) - GRE
Symptom
Table squeaks creaks scrapes is noisy when driven in or out of the gantry. Table squeaks creaks scrapes is noisy when driven is or out of the gantry.
Error message
Error: 260112011 Received Table Rx but the Table was NOT READY Error : 260112011 Received Table Rx but the Table was NOT READY Thu Sep 1 08:49:43 2005 Error: 260112011 Host: tgp Process: tgp_subsys File: uif_table_tilt_mgr.c Line: 3197 Thu Sep 1 08:49:44 2005 Host : Table Gantry Processor Ermes # : 260112011 Exception Class : Soft Severity : Pri/Soft File : uif_table_tilt_mgr.c Line# : 3197 Function : No System Function Reported Scan Type : Helical Scan: 8439/4/1 Received Table Rx but the Table was NOT READY for Scanning. Error: 260115185 Cradle velocity is out of tolerance Error. 260115185 Cradle velocity is out of tolerance cradle_position(um) : 1272744 target_position(um) : 1349271 velocity (um/s) : 75000 fpga status : 0x8104
Applies to
- Models
- LightSpeed, VCT
- Product
- LightSpeed 3.X (Ultra, Plus, QX/i) - GRE Always 4 or 8 slice MDAS. H2_P_M4 H2_P_M8 LightSpeed 3.X - GRE Method of visual identification Small rounded gantry similar in appearance to LS 2.X and 4.X. Always has an MDAS4 or MDAS8 Method of remote or software identification - See attachment below for a complete list of software commands and typical results. check_config “swhwinfo” will have the following new switches available with the VCT M4 and PF 1.5 M3 software release (software release deploying this “swhwinfo” capability is “06MW03.?”): · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) -h or –help = Outputs complete details about all the available switches associated with swhwinfo swhwinfo –c –m –o -da Always has an MDAS4 or MDAS8 List of Supported Console Types GOC3 Will have a DARC, SDDA and IG GOC4 Will have a DARC 2 and IG List of softwares the product can run 07MW11.10 SP3 06MW29.7 - obsolete 06MW03.5 - obsolete 05MW14.5 - obsolete 04MW44.9 - obsolete 04MW13.7 - obsolete FAQ's Table weight limit - Up to 400 lb. (180 kg) with ± .25 mm positional accuracy. 450Ib (205 kg) max weight Tube type - D3186T Current production details - See Technical Reference Manual found on the Common Document Library Tips and workarounds, where to find it - Common Document Library(CDL) . Search for the latest FMI software release. In the furnished materials will be the list of various manuals with part numbers for the various languages. Example: English versions 2211223-100 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Component
- 46-208580P19 & 46-208580P6 CAM FOLLOWER See long description for details Part #: 46-208580P19 Part Type: GP CONSUMABLES Part Weight: 0.20 KGM Repairable: No Returnable: No Hazardous Material: N Description: CAM FOLLOWER FRU: Yes Status: Orderable ====================== Parts Offered as:Current: 46-208580P19 Harvested: Not Available Exchange: Not Available Comments: FLS - IBS PART Part #: 46-208580P6 Part Type: GP CONSUMABLES Part Weight: 0.02 KGMRepairable: NoReturnable: NoHazardous Material: N Description: CAM FOLLOWER FRU: YesStatus: Orderable======================Parts Offered as:Current: 46-208580P6 Harvested: Not AvailableExchange: Not AvailableComments: Not Available 2259859 CARRIAGE_RAIL, (REF 46-278261P1) See long description for details Part #: 2259859 Part Type: GP CONSUMABLES Part Weight: 6.00 KGM Repairable: No Returnable: No Hazardous Material: N Description: CARRIAGE_RAIL, (REF 46-278261P1) FRU: Yes Status: Orderable ====================== Parts Offered as:Current: 2259859 Harvested: Not Available Exchange: Not Available Comments: FLS - CARRIAGE RAIL (REF 46-278261P1) ADDED. USED ON H2TABLE LCC. ASIA HAS IDENTIFIED THIS AS A LINKED PART (SEE 46-278261P1).AWAITING CONFIRMATION ON GL18.MSA8429 11/8/01 WILL START DEPLOYMENT FROM ASIA ON FW51,01. MS20544 1/31/02 THIS P/N IS BACKWARD COMPATIBLE WITH 46-278261P1. USE EXISTING STOCK FIRST OF 46-278261P1. PER CSV (MS20544). MSA8429 06/19/02
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.