GE Healthcare · CTLightSpeedVCT290012010
LightSpeed 7.x (VCT, VCT Select, Pro32)
Symptom
Fast Cals Aborted See Long Description Scanner Hardware stopped Scan during Fast Cals
Error message
Error: 290012010 Wrong corr type for det XX row XX correction type 0 (BAD_DET_NO_CORR) Sun Apr 12 13:37:20 2009 Error: 290012010 ig1 image_generation BadDet.cpp 292 Wrong corr type for det 35 row 1 correction type 0 (BAD_DET_NO_CORR) exam/series/scan = -1/-1/0 Sun Apr 12 13:37:20 2009 Error: 290012010 ig1 image_generation BadDet.cpp 292 Wrong corr type for det 36 row 1 correction type 0 (BAD_DET_NO_CORR) exam/series/scan = -1/-1/0 Description: This error is usually a secondary result of a detector or group of pixels that have failed one of the exclusion criteria from the maRatio’s test run in Fastcal, Detailed Cal, or DAStools. In this case there would be errors in the log above this “Wrong corr type” error that would define which specific detector module has a failure. The “Wrong corr type” error above is the image generation process saying it can not process the scan data as delivered because image generation doesn’t know how to correct for the bad data marked identified as a bad pixel in the data chain. If there does not seem to be any bad pixel messages to identify the failing detector module, the right module can be decoded from the error above by taking the detector # and add
Applies to
- Models
- LightSpeed, VCT
- Product
- LightSpeed 7.x (VCT, VCT Select, Pro32) V40_H_V64_G_GTM V40_H_V64_G_GTL V40_H_V32_G_GTM V40_H_V32_G_GTL V40_H_H64_G_GTM V40_H_H64_G_GTL V40_H_HS64_G_G Product Name: LightSpeed 7.x (VCT, VCT Select, Pro32) Product photographs Method of remote or software identification - See attachment for a complete list of software commands and typical results. check_config swhwinfo “swhwinfo” will have the following new switches available with the VCT M4 and PF 1.5 M3 software release (software release deploying this “swhwinfo” capability is “06MW03.?”): · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) · -h or –help = Outputs complete details about all the available switches associated with swhwinfo · swhwinfo –c –m –o -da List of Supported Console Types GOC5 Will have a VDARC and VIG GOC6 Will have a VDIG List of softwares the product can run 09MW08.10 09MW08.11 08MW33.2 07MW18.4 06MW03.4 05MW31.6 FAQ's Table weight limit - Up to 500 lb. (227 kg) with ± .25 mm positional accuracy Tube type - D3194T D3193T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system. Done acording to template
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required