GE Healthcare · CTLightSpeedVCT183797418379751837976183797718379781837979
LightSpeed 7.x (VCT, VCT Select, Pro32)
Symptom
Error during Software Load From Cold (LFC)
Error message
error: unpacking of archive failed on file /tftpboot/initrd.img.vct;4a54c7c7: cpio: read failed - Input/output error See long description for details Software load errors: Application Disk Failed to load with the following errors: Helios_VCT_Product-vism3-6.i386.rpm error: unpacking of archive failed on file /tftpboot/initrd.img.vct;4a54c7c7: cpio: read failed - Input/output error. All failed to unpack /tftpboot/initrd.img.vct and messages reported the same blocks in all three systems. Jul 8 10:41:35 bay14 kernel: Buffer I/O error on device sr0, logical block 1837974 Jul 8 10:41:35 bay14 kernel: Buffer I/O error on device sr0, logical block 1837975 Jul 8 10:41:35 bay14 kernel: Buffer I/O error on device sr0, logical block 1837976 Jul 8 10:41:35 bay14 kernel: Buffer I/O error on device sr0, logical block 1837977 Jul 8 10:41:35 bay14 kernel: Buffer I/O error on device sr0, logical block 1837978 Jul 8 10:41:35 bay14 kernel: Buffer I/O error on device sr0, logical block 1837979 Jul 8 10:41:35 bay14 kernel: Buffer I/O error on device sr0, logical block 1837980 Jul 8 10:41:35 bay14 kernel: Buffer I/O error on device sr0, logical block 1837981 Jul 8 10:41:35 bay14 kernel: Buffer I/O error
Applies to
- Models
- LightSpeed, VCT
- Product
- LightSpeed 7.x (VCT, VCT Select, Pro32) V40_H_V64_G_GTM V40_H_V64_G_GTL V40_H_V32_G_GTM V40_H_V32_G_GTL V40_H_H64_G_GTM V40_H_H64_G_GTL V40_H_HS64_G_G Product Name: LightSpeed 7.x (VCT, VCT Select, Pro32) Product photographs Method of remote or software identification - See attachment for a complete list of software commands and typical results. check_config swhwinfo “swhwinfo” will have the following new switches available with the VCT M4 and PF 1.5 M3 software release (software release deploying this “swhwinfo” capability is “06MW03.?”): · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) · -h or –help = Outputs complete details about all the available switches associated with swhwinfo · swhwinfo –c –m –o -da List of Supported Console Types GOC5 Will have a VDARC and VIG GOC6 Will have a VDIG List of softwares the product can run 09MW08.10 09MW08.11 08MW33.2 07MW18.4 06MW03.4 05MW31.6 FAQ's Table weight limit - Up to 500 lb. (227 kg) with ± .25 mm positional accuracy Tube type - D3194T D3193T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system. Done acording to template
- Software
- 09MW08.10 for GOC6 LightSpeed VCT 7.2 (64 Slice Only) June 2009 Inital M3 release. This software is now obsolete, this site should be upgraded to 11HW12.5 software released via FMI 25427 09MW08.10 for GOC6 LightSpeed VCT 7.2 (64 Slice Only) June 2009 Inital M3 release. LightSpeed 7.2 ( 09MW08.10 ) Software Release supports GOC6 consoles used on VCT 64, VCT XT, VCT XTe and VCT Std. - LightSpeed 7.2 (09MW08.10 )Software for GOC6 Collector 5328048 Rev 3 Includes OS and Application CD's - Operating System Linux 5.3.8 Software CD 5323584 Rev 1 - Application LightSpeed VCT GOC6 DVD 5336533 Rev 3 - Class C LightSpeed 7.2 5336535 Rev 2 - Class M LightSpeed 7.2 5336536 Rev 2 An On-site/Remote identification aid . (Example: check_config) Result from check_config or swhwinfo 09MW08.10.V40_H_H64_G_GTM 09MW08.10.V40_H_H64_G_GTM Please create an ITRAK report for any software related issues
- Component
- 5328048 : VCT VISION Software Collector See long description for details Part #: 5328048 Part Type: GP CONSUMABLES Part Weight: 0.00 LBR Repairable: No Returnable: No Hazardous Material: N Description: VCT VISION Software Collector FRU: Yes Status: Orderable 1) Try ordering from Global parts: Order 5328048 (No Rating Plate ) * Global Parts currently not available: Description : VCT VISION Software Collector FRU: Yes 2) Temporary Solution: Contact Kevin Swain or Dave Palermo for urgent software orders. 3) A 3rd option is to Order 5328048 (No Rating Plate ) Software collector from Coakley via GEMSBuy GEMSBuy - http://sss.corporate.ge.com:8005/OA_HTML/login.jsp
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.