LightSpeed 4.X - GRE
Symptom
Exam/Series/Image did not show up in the Patient List Select (image browser). See Long Description for Details Exam/Series/Image did not show up in the Patient List Select (image browser). The customer did a refresh of the browser and the images were then shown in the list. Selecting the images and trying to display them resulted in a message “No Valid Selection”. User scanned a series and the images were generated and displayed in the autoview view port. The issue is that the Exam/Series/Image did not show up in the Patient List Select (image browser). The customer did a refresh of the browser and the images were then shown in the list. Selecting the images and trying to display them resulted in a message “No Valid Selection”. Images did get put in the database but were not accessible by the customer. Reboot did not fix this problem
Error message
Error: 200502013 Lock Exam request failed for exam path See long description for full error Sun May 27 07:59:55 2007 Error: 200502013 Host: cter Process: scanRx File: srx_sma_manage_image_space.c Line: 346 Function: Data Acquisition : OC Processing : Lock Exam request failed for exam path (e599487/). AiM call status = 3
Applies to
- Models
- LightSpeed
- Product
- LightSpeed 4.X - GRE See Long Description for detailed information - H2_P_M16 Product Name: LightSpeed 4.X with GRE Product Photographs GE HEALTHCARE Method of remote or software identification - See attachment below for a complete list of software commands and typical results 1. check_config 2 . swhwinfo “swhwinfo” will have the following switches: · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) -h or –help = Outputs complete details about all the available switches associated with swhwinfo swhwinfo –c –m –o -da List of Supported Console types: GOC3 (GRE) GOC4 (GRE) List of software the product can run: 07MW11.10 SP2.0, SP3.0, SP3.1 FAQ's Table weight limit - 180 kg (400 lbs) normal operation - 205 kg (450 lbs) maximum allowed with decreased accuracy Tube type - D3186T D3186T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required