Pular para o conteúdo principal
GE Healthcare · CTLightSpeed260111604

LightSpeed 5.X (80/100kW)

Symptom

"Scanner Hardware Stopped Scan" DURING SMARTVIEW prep WITH Interventional Hand Held Control (IHHC) failed to enable Scanner Hardware Stopped Scan DURING SMARTVIEW prep WITH Interventional Hand Held Control (IHHC) failed to enable See the log description for the full error code Mon Sep 19 10:35:34 2005 Error: 182700 Suite: CT01 Host: ETC Hand Held Control Process: Diag Exec File hc_e xec.c 1.38 No Method Line: 595 Function: Diagnostics OPERATOR INPUT/OUTPUT : Tableside Operator Interface Test Name: Unique ID: 58982 Iteration: 1 Exception Level: Hard Time: 18945 Error Type: Firmware Interventional Hand Held Control (IHHC) failed to enable. Verify IHHC is connected to scanner. If IHHC is not connected to scanner, connect IHHC to scanner. If IHHC is connected to scanner, disconnect IHHC from scanner and reconnect IHHC to scanner. Thu Aug 14 12:26:27 2008 Error: 182701 Host: Process: gr:RECEIVE:firmware File: hc_wdog.c 1.7 2/16/99 Line: 255 Function: No System Function Reported Scan: 25796/3/0 Type: None/Unknown Exception Level: Pri/Most Severe Time: 12:26:26:920 Log Series: 418 Interventional Hand Held Control (IHHC) Watchdog Timeout. The IHHC has been disabled. HW/SW Error: Probable hardware, possible software, problem

Error message

Error: 260111604 Tx retries used. See long description for a full sample error. Wed Jul 2 11:44:36 2008 Error: 260111604 Host: tgp Process: tgp subsys File: hc tx.c Line: 143 Wed Jul 2 11:44:36 2008 Host : Table Gantry Processor Ermes # : 260111604 Exception Class : Abort Severity : Primary File : hc tx.c Line# : 143 Function : No System Function Reported Scan Type : Axial Scan: 4239/3/1 Tx retries used.

Applies to

Models
LightSpeed
Product
LightSpeed 5.X (80/100kW) LightSpeed 5.X (80/100kW) ~ Use with both MDAS and GDAS ~ GRE Console HP_H_G16 HP_H_M16 HP_O_M16 LightSpeed 5.X (100kW) GDAS16 with GRE Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
Component
2199947 CT SONATA HAND HELD CONTROLLER CT SONATA HAND HELD CONTROLLER Part number 2199947 CT SONATA HAND HELD CONTROLLER Part number 2199947
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.

7-day free trial · no credit card required

Related GE Healthcare CT issues