GE Healthcare · CTLightSpeed290012000260118213260118214
LightSpeed 5.X (60kW)
Symptom
A grinding, rumbling, squealing, clicking, or other noise is heard only during gantry rotation - document in RFS - critical issue see long description for more detail. A grinding,rumbling, squealing, clicking, or other noise is heard only during gantry rotation. Gantry speed or velocity errors are NOT reported to the customer or the gesyslog. System will still scan ok but customer just complains of excessive noise from gantry. Sound volume or quality can change with rotation speed.
Error message
Error: 290012000 View corrections were applied in view # The errror 290012000 "View corrections were applied in view number" message indicate the Image Generator or recon software detected a corrupt view and has applied view corrections to image. This Error alone does not indicate a problem. See service note SN05102815a. Wed Feb 13 13:46:25 2008 Error: 290012000 Host: ig3 Process: image_generation File: MissedView.cpp Line: 129 View corrections were applied in view 5400. exam/series/scan = 345/2/1 From SN05102815a Error code 290012000 is a status notification that Recon has made a correction to maintain image quality. This error is transparent to the Customer and has no effect on system performance. This condition is generated when the IG reads in the scan data and checks the KV signal for each view. If the KV signal drops below a certain threshold, a correction is made by design. The low KV signal can be defined as a "High Voltage Disturbance". Do not assume the tube is the source of the problem. A healthy tube will typically generate 2000 to 3000 of these events during its normal life. Other potential sources for high voltage disturbances are the Jedi Generator, HV Tank, and cabl
Applies to
- Models
- LightSpeed
- Product
- LightSpeed 5.X (60kW) LightSpeed 5.X (60kW) ~ Use with MDAS or GDAS HP_P_G4 HP_P_G8 HP_P_G16 HP_P_M16 LightSpeed 5.X 60KW G-DAS16 with GRE Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required