Can Not Restore Exam Images From MOD Due to Archive Device Set Wrong.
Symptom
Can Not Restore Exam Images From MOD See long description Site completed the exam, removed unwanted series and archived to MOD but exam was not found in browser when they tried to network to another host. No errors in error log indicating any problems or with imslog indicating the exam was removed. arslog indicates successfully archive exam with the following: MESSAGE from Process 6158>> Wed Sep 24 13:11:37 2008 (ArchiveDevice.c:6558) Start Saving: 2861/3 MESSAGE from Process 11540>> Wed Sep 24 13:11:38 2008 (arscommand.c:2127) Saved series 2861/3 MESSAGE from Process 6158>> Wed Sep 24 13:11:38 2008 (ArchiveDevice.c:6558) Start Saving: 2861/4 MESSAGE from Process 11545>> Wed Sep 24 13:11:42 2008 (arscommand.c:2127) Saved series 2861/4 MESSAGE from Process 6158>> Wed Sep 24 13:11:42 2008 (ArchiveDevice.c:6558) Start Saving: 2861/5 MESSAGE from Process 11555>> Wed Sep 24 13:11:49 2008 (arscommand.c:2127) Saved series 2861/5 MESSAGE from Process 6158>> Wed Sep 24 13:11:49 2008 (ArchiveDevice.c:6558) Start Saving: 2861/6 MESSAGE from Process 11573>> Wed Sep 24 13:11:54 2008 (arscommand.c:2127) Saved series 2861/6 MESSAGE from Process 6158>> Wed Sep 24 13:11:54 2008 (ArchiveDevice.c:6558) Start Saving: 2861/99 MESSAGE from Process 11582>> Wed Sep 24 13:11:55 2008 (arscommand.c:2127) Saved series 2861/99 Site tried to restore exam 2861 multiple times but arslog continually repeats the following: MESSAGE from Process 6618>> Wed Sep 24 13:35:08 2008 (ArchiveDevice.c:5520) Start Restoring: 2861 MESSAGE from Process 6618>> Wed Sep 24 13:35:08 2008 (ImageInstall.c:485) Image already exists, pulled image discarded: Site rebooted with same results. Image already exists, pulled image discarded:
Applies to
- Models
- Signa
- Product
- Signa LX Signa LX Product can be used with 8.x and 9.x systems.
- Software
- 9.1 For Signa LX product only
- Area
- MR
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare MR issues
- Running grafidy3, and find there are spikes on the waveforms in the manual prescan display, both windows.
- Fails to Scan with TORSO Coil.
- The Carriage Fails to Advance to Latch to the Table and to Retract When it is Raised, Undocked or Lowered.
- AE title has changed on destination host.
- CWA ID100315. Auto and Manual Prescan Fails.
- What is the Acoustic Noise Level in the Ovation Magnet.